Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: PINKSTON TADD ROOFING SERVICES INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PINKSTON TADD ROOFING SERVICES INC. in 437 WEST STATE ST., SYCAMORE, IL 60178 (NAICS 238160). OSHA activity number 337068381.

Watch Pinkston Tadd Roofing Services INC. — free Get an email when a new federal OSHA severe-injury report for Pinkston Tadd Roofing Services INC. is published. One employer, no account, unsubscribe in one click.
Site address
437 WEST STATE ST.
City
SYCAMORE
State
IL
ZIP
60178
Mailing
407 INDUSTRIAL DRIVE, DEKALB, IL 60115
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
3
Ownership type
A

2 citations on file for this inspection.

1926.501 B10

Serious Gravity 10 1 instance 2 exposed
Issued
Penalty
Initial $2800.00 · Current $1680.00 Reduced
29 CFR 1926.501(b)(10):     Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and fuardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system.  Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system.    At a jobsite in Sycamore, Illinois employees conducting commercial roofing operations approximately 30 feet above grade were not utilizing any method of fall protection.    There is no abatement certification or documentation required for this item.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1926.1053 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $1600.00 · Current $960.00 Reduced
29 CFR 1926.1053(b)(1):     Where (a) portable ladder(s) was/were used for access to an upper level landing surface and the ladders length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigied support that will not deflect, and/or a grasping device was not provided to assist emmployees in mounting and dismounting the ladder.    At a jobsite in Sycamore, Illinois employees utilizing an extension ladder to gain access to a flat commercial roof did not extend the ladder a minimum of 3 feet above the landing surface.    Abatement certification is required of this item in accordaqnce with the requirements of 29 CFR 1903.19(c)