BRENTWOOD, NH —
OSHA Inspection: THE PROVIDER ENTERPRISES, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of THE PROVIDER ENTERPRISES, INC. in 127 PINE RD., BRENTWOOD, NH 03833 (NAICS 485210). OSHA activity number 337094593.
Where did this inspection happen?
- Establishment
- THE PROVIDER ENTERPRISES, INC.
- Site address
- 127 PINE RD.
- City
- BRENTWOOD
- State
- NH
- ZIP
- 03833
- Mailing
- 127 PINE RD., BRENTWOOD, NH 03833
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 485210
- Employees
- 270
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.107 C03
- Issued
- Penalty
- Initial $5000.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.107(c)(3): Space-heating appliances, steampipes, or hot surfaces shall not be located in a spraying area where deposits of cumbustable residues may readily accumilate. (a) Auto Body Shop - The Clean Burn Oil Furnace was located in the spray area.
Recent events (2)
- — I (S) $0
- — Z (S) $5000
1910.107 C04
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.107(c)(4): Electrical wiring and equipment shall conform to the provisions of this paragraph and shall otherwise be in accordance with subpart S of this part. (a) Auto Body Shop - The shop lights were not explosion proof.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.107 D04
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.107(d)(4): The fan-rotating element was not nonferrous or nonsparking or such material did not comprise or line the casing: (a) Auto Body Shop - The exhaust fan was not non-sparking.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.106 D03 II
- Issued
- Penalty
- Initial $4000.00 · Current $1500.00 Reduced
General-duty citation text
29 CFR 1910.106(d)(3)(ii): Storage cabinet(s) for flammable and combustible liquids were not designed or constructed to meet minimal fire resistance as required: (a) Auto Shops - The flammable storage cabnets were made of single walled file cabnets.
Recent events (2)
- — I (S) $1500
- — Z (S) $4000
1910.132 H01
- Issued
- Penalty
- Initial $3000.00 · Current $1500.00 Reduced
General-duty citation text
29 CFR 1910.132(h)(1): Except as provided by paragraphs (h)(2) through (h)(6) of this section, the protective equipment, including personal protective equipment (PPE), used to comply with this part, shall be provided by the employer at no cost to employees. (a) Auto shops - Employees were required to purchase safety gloves and safety glasses.
Recent events (2)
- — I (S) $1500
- — Z (S) $3000
1910.134 C
- Issued
- Abate by
- Penalty
- Initial $5000.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.134(c): The employer did not develop and implement a written respiratory protection program with required worksite-specific procedures and elements for required respirator use: (a) Auto Body shop - The employer did not have a written respiratory protection program.
Recent events (2)
- — I (O) $0
- — Z (S) $5000
More inspections in this industry (NAICS 485210)
LOUISVILLE, KY—2026-05-11
69105 - TRANSIT AUTHORITY OF RIVER CITY
SPOKANE, WA—2026-03-23
WA317990392 - SPOKANE PUBLIC TRANSPORTATION BENEFIT AREA
SPOKANE, WA—2026-03-03
WA317990093 - SPOKANE PUBLIC TRANSPORTATION BENEFIT AREA
PHILADELPHIA, PA—2026-03-02
SUNTECK TTS, LLC
SPOKANE, WA—2026-01-29
WA317989608 - SPOKANE PUBLIC TRANSPORTATION BENEFIT AREA
More inspections in NH
CONCORD, NH—2026-07-10
C.C. TOMATOES
FRANCESTOWN, NH—2026-07-10
JM BUILDERS LLC
FRANCESTOWN, NH—2026-07-10
D&D INSULATION, LLC
NORTHFIELD, NH—2026-07-03
JP PEST SERVICES
CONCORD, NH—2026-07-01
REYES CARPENTRY, LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337094593.