CHICAGO, IL —
OSHA Inspection: EXTERIOR RENOVATION EXPERTS, INC.
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of EXTERIOR RENOVATION EXPERTS, INC. in 960 N. RACINE AVENUE, CHICAGO, IL 60610 (NAICS 238140). OSHA activity number 337141592.
Where did this inspection happen?
- Establishment
- EXTERIOR RENOVATION EXPERTS, INC.
- Site address
- 960 N. RACINE AVENUE
- City
- CHICAGO
- State
- IL
- ZIP
- 60610
- Mailing
- 1801 S. ASHLAND AVENUE, CHICAGO, IL 60608
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 4
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.451 E01
- Issued
- Abate by
- Penalty
- Initial $2200.00 · Current $2200.00
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access: a. On or about October 30, 2012- at a jobsite located at 960 N. Racine Chicago, IL - employees were performing tuckpointing activities from a tubular welded framed scaffolding that was not equipped with an additional ladder of were exposed to approximately nineteen (19) feet five (5) inches fall hazards.
Recent events (1)
- — Z (S) $2200
1926.451 G04 I
- Issued
- Abate by
- Penalty
- Initial $2200.00 · Current $2200.00
General-duty citation text
29 CFR 1926.451(g)(4)(i): Guardrail systems shall be installed along all open sides and ends of platforms. Guardrail systems shall be installed before the scaffold is released for use by employees other than erection/dismantling crews: a. On or about October 30, 2012- at a jobsite located at 960 N. Racine Chicago, IL - employees were performing tuckpointing activities from a tubular welded framed scaffolding that was not equipped with midrails or endrails, thereby exposing the employees to fall hazards of approximately nineteen (19) feet five (5) inches.
Recent events (1)
- — Z (S) $2200
More inspections at EXTERIOR RENOVATION EXPERTS, INC.
CHICAGO, IL—2011-05-24 00:00:00
EXTERIOR RENOVATION EXPERTS, INC.
CHICAGO, IL—2010-07-09 00:00:00
EXTERIOR RENOVATION EXPERTS, INC.
View EXTERIOR RENOVATION EXPERTS, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238140)
MARIANNA, FL—2026-07-13
PRIMETIME MOBILE MASONRY LLC
LOMPOC, CA—2026-07-10
UNKNOWN EMPLOYER
FREEHOLD, NJ—2026-07-10
CRAIG'S MASONRY & HARDSCAPE LLC
CINCINNATI, OH—2026-07-09
ALL AMERICAN CONCRETE LLC
NEW YORK, NY—2026-07-08
JEY CONSTRUCTIONS WORKS CORP
More inspections in IL
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
GRANITE CITY, IL—2026-07-13
UNITED STATES STEEL CORPORATION
DECATUR, IL—2026-07-10
TILLAMOOK ILLINOIS, LLC
NEW LENOX, IL—2026-07-10
A.D GENERAL CONSTRUCTION LLC
LOCKPORT, IL—2026-07-09
ROBERTO GOMEZ DBA ROBERTO GOMEZ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337141592.