RUSSELLVILLE, AL —
OSHA Inspection: FMI PRODUCTS, LLC
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of FMI PRODUCTS, LLC in 1769 EAST LAWRENCE STREET, RUSSELLVILLE, AL 35654 (NAICS 333414). OSHA activity number 337162390.
Where did this inspection happen?
- Establishment
- FMI PRODUCTS, LLC
- Site address
- 1769 EAST LAWRENCE STREET
- City
- RUSSELLVILLE
- State
- AL
- ZIP
- 35654
- Mailing
- 1769 EAST LAWRENCE STREET, RUSSELLVILLE, AL 35654
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333414
- Employees
- 71
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.23 D01
- Issued
- Abate by
- Penalty
- Initial $3060.00 · Current $1836.00 Reduced
General-duty citation text
29 CFR 1910.23(d)(1): Every flight of stairs having four or more risers was not equipped with standard stair railings or standard handrails as specified in paragraphs (d)(1)(i) through (v) of this section: (a) On or about 11/14/12 - Fiber area, a standard railing was not installed on the stairs leading to the two large mix tanks.
Recent events (2)
- — I (S) $1836
- — Z (S) $3060
1910.23 C01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards:Note: Toeboards are only required when persons can pass, there is moving equipment or there is equipment with which falling materials could create a hazard. (a) On or about 11/14/12 - Mezzanine tank area, the standard railing installed along the mezzanine platform was missing a midrail.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.132 A
- Issued
- Abate by
- Penalty
- Initial $2295.00 · Current $1377.00 Reduced
General-duty citation text
29 CFR 1910.132(a): Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered: (a) On or about 10/31/12- Resistance weld lines, protective equipment, such as but not limited to, leather apron, fire resistant boot protectors or spats, insulated weld gloves and arm protectors were not utilized where employees are exposed to heat and burns from radiated sparks during resistance welding. (b) On or about 10/31/12- Sealed air instapak line, protective clothing, such as but not limited to, aprons or coveralls were not utilized where employees are exposed to isocynate containing materials during packing bag breakage.
Recent events (2)
- — I (S) $1377
- — Z (S) $2295
1910.1200 F05 I
- Issued
- Abate by
- Penalty
- Initial $2295.00 · Current $1377.00 Reduced
General-duty citation text
29 CFR 1910.1200(f)(5)(i): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the identity of the hazardous chemical(s) contained therein: (a) On or about 10/31/12 - Dip tank, the tank containing the paint was not labeled with the name of the material contained within the tank. (b) On or about 11/14/12 - Fiber area, process tanks including the mixing tanks and holding tanks were not labeled with the name of the material contained within the tanks.
Recent events (2)
- — I (S) $1377
- — Z (S) $2295
1910.1200 F05 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(f)(5)(ii): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the appropriate hazard warnings: (a) On or about 10/31/12 - Dip tank, the tank containing the paint was not labeled with the hazard of the material contained within the tank. (b) On or about 11/14/12 - Fiber area, process tanks including the mixing tanks and holding tanks were not labeled with the hazard of the material contained within the tanks.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 H
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(h): Employees were not provided effective information and training as specified in 29 CFR 1910.1200(h)(1) and (-2) on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard was introduced: (a) On or about 10/31/12 - Production areas, employees exposed to paints, cement refractory mix, and resistance weld fume had not been provided training about potential exposures in the workplace.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 K06
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.134(k)(6): The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, in written or oral format to employees who wear respirators when such use was not required by the employer: (a) On or about 10/31/12 - Log stain spray booth, information contained in Appendiix D had not been provided to employee(s) supplied a Moldex 2600 face-filtering respirator to use when spraying stain.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1026 D01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
0691
General-duty citation text
29 CFR 1910.1026(d)(1): The employer did not determine, in accordance with either paragraph (d)(2) or (d)(3) of this section, the 8-hour TWA exposure for each employee exposed to chromium (VI): (a) On or about 11/14/12 - Line B and pipe line, exposure monitoring had not been conducted for employees performing resistance welding.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at FMI PRODUCTS, LLC
SANTA ANA, CA—2011-12-29 00:00:00
FMI PRODUCTS LLC
View FMI PRODUCTS, LLC's full OSHA safety record →
More inspections in this industry (NAICS 333414)
MORRISVILLE, VT—2026-05-18
HEARTHSTONE QUALITY HOME HEATING PRODUCTS, INC.
BURLINGTON, WA—2026-05-14
WA317991146 - SILFAB SOLAR WA INC
EDEN, NC—2026-04-29
161122 - WM TECHNOLOGIES, LLC
CRANSTON, RI—2026-04-14
TACO, LLC
BRAINTREE, MA—2026-03-31
NORTHEAST AIR SOLUTIONS
More inspections in AL
CLANTON, AL—2026-07-13
UBIQUE TECHNOLOGIES, INC.
IRONDALE, AL—2026-07-13
FATHER NATURE LANDSCAPES OF BIRMINGHAM, INC.
GARDENDALE, AL—2026-07-09
ANDINO'S IRON WORKERS, LLC
CULLMAN, AL—2026-07-09
ALFREDO PICHARDO BLANCO
MOBILE, AL—2026-07-09
FLEXICREW TECHNICAL, LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337162390.