2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: PHILIP ORTIZ

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PHILIP ORTIZ in 68 BONHOMIE ROAD, HATTIESBURG, MS 39401 (NAICS 238140). OSHA activity number 337209613.

Watch Philip Ortiz — free Get an email when a new federal OSHA severe-injury report for Philip Ortiz is published. One employer, no account, unsubscribe in one click.
Establishment
PHILIP ORTIZ
Site address
68 BONHOMIE ROAD
City
HATTIESBURG
State
MS
ZIP
39401
Mailing
1729 MCNAIR ST., MEMPHIS, TN 38108
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
6
Ownership type
A

4 citations on file for this inspection.

1926.300 B04 II

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $1600.00
29 CFR 1926.300(b)(4)(ii):     The point of operation of machines whose operation exposes an employee to injury, shall be guarded. The guarding device shall be in conformity with any appropriate standards therefor, or, in the absence of applicable specific standards, shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle.      a. Club House, Mill Creek Place Apartments, Hattiesburg MS - On or about November 1, 2012 a DeWalt chop saw had a piece of wood wedged in the upper guard to prevent the guard from covering the blade when cutting bricks.
Recent events (1)
  • — Z (S) $1600

1926.451 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $1600.00
29 CFR 1926.451(b)(1):     Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:    a. Club house, Mill Creek Place Apartments, Hattiesburg MS - On or about November 1, 2012 employees were observed working from a scaffold platform that was not fully planked.
Recent events (1)
  • — Z (S) $1600

1926.451 C02

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $1600.00
29 CFR 1926.451(c)(2):     Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.    a. Club house, Mill Creek Place Apartments, Hattiesburg MS - On or about November 1, 2012 a scaffold located on the front side of the club house did not have baseplates.
Recent events (1)
  • — Z (S) $1600

1926.451 C02 I

Serious Gravity 10 3 instances 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(c)(2)(i):     Footings shall be level, sound, rigid, and capable of supporting the loaded scaffold without settling or displacement.    a. Club house, Mill Creek Place Apartments, Hattiesburg MS - On or about November 1, 2012 the baseplates of a welded frame scaffold located at the back of the club house were not sitting squarely on the mudsills.  The baseplates were over the edge of the mudsills.
Recent events (1)
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337209613.