Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: KNAPP ROOFING

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of KNAPP ROOFING in 34 GERARD STREET, MILFORD, CT 06460 (NAICS 238160). OSHA activity number 337226021.

Watch Knapp Roofing — free Get an email when a new federal OSHA severe-injury report for Knapp Roofing is published. One employer, no account, unsubscribe in one click.
Establishment
KNAPP ROOFING
Site address
34 GERARD STREET
City
MILFORD
State
CT
ZIP
06460
Mailing
245 FORD STREET, MILFORD, CT 06460
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
3
Ownership type
A

3 citations on file for this inspection.

1926.451 A01

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.451(a)(1): Except as provided in paragraphs (a)(2), (a)(3), (a)(4), (a)(5) and (g) of this section, each scaffold and scaffold component shall be capable of supporting, without failure, its own weight and at least 4 times the maximum intended load applied or transmitted to it.    WORKSITE: The roof bracket scaffold and its components, installed on the 11 in 12 pitch roof were not capable of supporting the total load applied to the scaffold.    On or about November 5, 2012, while replacing underlayment and shingles on the 11 in 12 pitch roof the 2X10 board being used on the roof bracket scaffold failed, causing two employees who were not protected by an appropriate fall protection system to fall 17 feet to the ground.
Recent events (1)
  • — Z (S) $2800

1926.451 G01 VII

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(g)(1)(vii): For all scaffolds not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, each employee shall be protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.    WORKSITE: The employees, installing shingles from the roof bracket scaffold on the 11 in 12 pitch roof were exposed to a 17 foot fall without adequate fall protection.    On or about November 5, 2012, while replacing underlayment and shingles on the 11 in 12 pitch roof the 2X10 board being used on the roof bracket scaffold failed, causing two employees who were not protected by an appropriate fall protection system to fall 17 feet to the ground.
Recent events (1)
  • — Z (S) $0

1926.501 B13

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. WORKSITE: The employees, installing shingles from the roof bracket scaffold on the 11 in 12 pitch roof were exposed to a 17 foot fall without adequate fall protection.    WORKSITE: The employees installing shingles on peak and at the rake edge of the 11 in 12 pitch roof were exposed to fall hazards exceeding 17 feet without an appropritate fall protection system.
Recent events (1)
  • — Z (S) $0

View KNAPP ROOFING's full OSHA safety record →