SAN ANTONIO, TX —
OSHA Inspection: JESUS CARDENAS
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of JESUS CARDENAS in 5511 PECAS SPRINGS, SAN ANTONIO, TX 78249 (NAICS 236116). OSHA activity number 337270615.
Where did this inspection happen?
- Establishment
- JESUS CARDENAS
- Site address
- 5511 PECAS SPRINGS
- City
- SAN ANTONIO
- State
- TX
- ZIP
- 78249
- Mailing
- 5903 DANNY KAYE DR #805, SAN ANTONIO, TX 78240
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236116
- Employees
- 8
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.451 B01
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1300.00 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): a) On or about November, 07, 2012, East corner of apartment building where tubular welded scaffold was not fully planked on the first tier exposing employees to a fall hazard. b) On or about November, 07, 2012, Northwest side of an apartment building where tubular welded scaffold was not fully planked at the corner on the first, second, and third tier from gable (a) to the main scaffold exposing employees to a fall hazard. c) On or about November, 07, 2012, Northwest side of an apartment building where tubular welded scaffold was not fully planked at the corner on the second and third tier from gable (b) to the main scaffold exposing employees to a fall hazard. d) On or about November, 07, 2012, Southeast side of an apartment building where tubular welded scaffold was not fully planked at the corner on the second and third tier from the gable to the main scaffold exposing employees to a fall hazard. e) On or about November, 07, 2012, Northeast side of an apartment building where tubular welded scaffold was not fully planked at the corner on the first and third tier from the gable to the main scaffold exposing employees to a fall hazard.
Recent events (2)
- — I (S) $1300
- — Z (S) $2000
1926.451 C02 I
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $1820.00 Reduced
General-duty citation text
29 CFR 1926.451(c)(2)(i): Footings were not level, sound, rigid, and capable of supporting the loaded scaffold without settling or displacement: a) On or about November 7, 2012, Northwest side of an apartment building where tubular welded scaffold footing on the left side of the gable (a) were attached to the structure by nails attached to a 2x4 on an 8:12 pitch roof exposing employees to a fall hazard. b) On or about November 7, 2012, Northwest side of an apartment building where tubular welded scaffold footing on the right side of the gable (a) were attached to the structure by nails attached to a 2x4 on an 8:12 pitch roof exposing employees to a fall hazard. c) On or about November 7, 2012, Northwest side of an apartment building where tubular welded scaffold footing on the left side of the gable (b) were attached to the structure by nails attached to a 2x4 on an 8:12 pitch roof exposing employees to a fall hazard. d) On or about November 7, 2012, Northwest side of an apartment building where tubular welded scaffold footing on the right side of the gable (b) were attached to the structure by nails attached to a 2x4 on an 8:12 pitch roof exposing employees to a fall hazard.
Recent events (2)
- — I (S) $1820
- — Z (S) $2800
1926.452 C02
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1300.00 Reduced
General-duty citation text
29 CFR 1926.452(c)(2): All brace connections were not secured: On or about 11/07/2012, employees were exposed fall, struck by, or caught in or between hazards while working on the North West side of an apartment building located right behind the Carbon Construction trailer. The first level of the scaffold cross brace had a broken pin which was then secured to the scaffold frame with electrical wire. There were five levels of scaffold above this point.
Recent events (2)
- — I (S) $1300
- — Z (S) $2000
1926.454 B
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1300.00 Reduced
General-duty citation text
29 CFR 1926.454(b): The employer did not have each employee who was involved in erecting, disassembling, moving, operating, repairing, maintaining, or inspecting a scaffold trained by a competent person to recognize any hazards associated with the work in question: On or about 11/07/2012, employees were exposed fall, struck by, or caught in or between hazards while working on an apartment building located right behind the Carbon Construction trailer. The first level of the scaffold cross brace had a broken pin which was then secured to the scaffold frame with electrical wire. There were five levels of scaffold above this point. The employer did not have a competent person inspect the scaffold prior to use.
Recent events (2)
- — I (S) $1300
- — Z (S) $2000
More inspections in this industry (NAICS 236116)
DELAVAN, WI—2026-07-15
TERONOMY BUILDERS, INC.
QUINCY, MA—2026-07-15
UNITEDWOR VM CONTRACTOR CORP
NEWTON, MA—2026-07-14
DELLBROOK CONSTRUCTION, LLC
NEWTON, MA—2026-07-14
GARDEN HOMES
PLAIN CITY, OH—2026-07-09
RUSCILLI CONSTRUCTION
More inspections in TX
WICHITA FALLS, TX—2026-07-16
UNITED RENTALS, INC.