1,224,460Inspections Most recent open 2026-07-13 Last loaded 2026-07-16
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: FLEXTM, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of FLEXTM, INC. in 909 FOURTH AVENUE SOUTH, WAHPETON, ND 58075 (NAICS 332312). OSHA activity number 337285415.

Watch Flextm, INC. — free Get an email when a new federal OSHA severe-injury report for Flextm, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
FLEXTM, INC.
Site address
909 FOURTH AVENUE SOUTH
City
WAHPETON
State
ND
ZIP
58075
Mailing
P.O. BOX 308, WAHPETON, ND 58075
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332312
Employees
40
Ownership type
A

7 citations on file for this inspection.

1910.22 A02

Serious Gravity 5 1 instance 15 exposed
Issued
Abate by
Penalty
Initial $3500.00 · Current $2100.00 Reduced
29 CFR 1910.22(a)(2): Floor(s) of workroom(s) were not maintained in a clean and, so far as possible, a dry condition:    (a) For employees exposed to potential slip and fall hazards in the press room from wet floors caused by leaks in the ceiling when it rains and/or snow melt at 909 Fourth Avenue South, Wahpeton, North Dakota.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3500

1910.22 B01

Serious Gravity 5 1 instance 15 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.22(b)(1): Aisles and passageways were not kept clear and in good repair, with no obstruction across or in aisles that could create a hazard:    (a) For employees exposed to potential struck-by hazards where forklifts, hand carts and portable tables tip over when transporting metal parts through uneven aisles and passageways between buildings at 909 Fourth Avenue South, Wahpeton, North Dakota.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.178 O01

Serious Gravity 5 1 instance 15 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.178(o)(1): The employer did not ensure that only stable or safely arranged loads were handled:    (a) For employees exposed to potential struck-by and/or crushing hazards where dies are not stable and fall off of forklifts during transport from storage shelves to power presses at 909 Fourth Avenue South, Wahpeton, North Dakota.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.217 C02 I B

Serious Gravity 10 1 instance 15 exposed
Issued
Abate by
Penalty
Initial $4900.00 · Current $2940.00 Reduced
29 CFR 1910.217(c)(2)(i)(b): Point-of-operation guards on a mechanical power press did not conform to the maximum permissible opening specified in Table 10 O-10:    (a) For employees exposed to potential struck-by and/or amputation hazards where the South Bend mechanical power press number 75 is operated with an approximate 13-inch by 19-inch opening within approximately 9 inches from the point-of-operation at 909 Fourth Avenue South, Wahpeton, North Dakota.
Recent events (2)
  • — I (S) $2940
  • — Z (S) $4900

1910.217 C02 V

Serious Gravity 10 1 instance 15 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.217(c)(2)(v): The hinged or movable section of an interlocked press barrier guard on a mechanical power press did not prevent opening of the interlocked section and reaching into the point-of-operation prior to die closure:    (a) For employees exposed to potential stuck-by and/or amputation hazards where the South Bend mechanical power press number 75 is operated with a hinged barrier guard without an operable interlock at 909 Fourth Avenue South, Wahpeton, North Dakota.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 B01 II

Serious Gravity 1 1 instance 15 exposed
Issued
Abate by
Penalty
Initial $2100.00 · Current $1260.00 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:    (a) For employees exposed to potential electrical shock hazards while operating the mechanical power press number 75 operator's control panel at 909 Fourth Avenue South, Wahpeton, North Dakota.
Recent events (2)
  • — I (S) $1260
  • — Z (S) $2100

1910.305 G01 IV A

Serious Gravity 1 1 instance 15 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:    (a) For employees exposed to potential electrical hazards where extensions cords are used as a permanent electrical source for lighting the work area on power press number 75 at 909 Fourth Avenue South, Wahpeton, North Dakota.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337285415.