WAHPETON, ND —
OSHA Inspection: FLEXTM, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of FLEXTM, INC. in 909 FOURTH AVENUE SOUTH, WAHPETON, ND 58075 (NAICS 332312). OSHA activity number 337285415.
Where did this inspection happen?
- Establishment
- FLEXTM, INC.
- Site address
- 909 FOURTH AVENUE SOUTH
- City
- WAHPETON
- State
- ND
- ZIP
- 58075
- Mailing
- P.O. BOX 308, WAHPETON, ND 58075
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332312
- Employees
- 40
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.22 A02
- Issued
- Abate by
- Penalty
- Initial $3500.00 · Current $2100.00 Reduced
General-duty citation text
29 CFR 1910.22(a)(2): Floor(s) of workroom(s) were not maintained in a clean and, so far as possible, a dry condition: (a) For employees exposed to potential slip and fall hazards in the press room from wet floors caused by leaks in the ceiling when it rains and/or snow melt at 909 Fourth Avenue South, Wahpeton, North Dakota.
Recent events (2)
- — I (S) $2100
- — Z (S) $3500
1910.22 B01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.22(b)(1): Aisles and passageways were not kept clear and in good repair, with no obstruction across or in aisles that could create a hazard: (a) For employees exposed to potential struck-by hazards where forklifts, hand carts and portable tables tip over when transporting metal parts through uneven aisles and passageways between buildings at 909 Fourth Avenue South, Wahpeton, North Dakota.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.178 O01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.178(o)(1): The employer did not ensure that only stable or safely arranged loads were handled: (a) For employees exposed to potential struck-by and/or crushing hazards where dies are not stable and fall off of forklifts during transport from storage shelves to power presses at 909 Fourth Avenue South, Wahpeton, North Dakota.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.217 C02 I B
- Issued
- Abate by
- Penalty
- Initial $4900.00 · Current $2940.00 Reduced
General-duty citation text
29 CFR 1910.217(c)(2)(i)(b): Point-of-operation guards on a mechanical power press did not conform to the maximum permissible opening specified in Table 10 O-10: (a) For employees exposed to potential struck-by and/or amputation hazards where the South Bend mechanical power press number 75 is operated with an approximate 13-inch by 19-inch opening within approximately 9 inches from the point-of-operation at 909 Fourth Avenue South, Wahpeton, North Dakota.
Recent events (2)
- — I (S) $2940
- — Z (S) $4900
1910.217 C02 V
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.217(c)(2)(v): The hinged or movable section of an interlocked press barrier guard on a mechanical power press did not prevent opening of the interlocked section and reaching into the point-of-operation prior to die closure: (a) For employees exposed to potential stuck-by and/or amputation hazards where the South Bend mechanical power press number 75 is operated with a hinged barrier guard without an operable interlock at 909 Fourth Avenue South, Wahpeton, North Dakota.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 B01 II
- Issued
- Abate by
- Penalty
- Initial $2100.00 · Current $1260.00 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: (a) For employees exposed to potential electrical shock hazards while operating the mechanical power press number 75 operator's control panel at 909 Fourth Avenue South, Wahpeton, North Dakota.
Recent events (2)
- — I (S) $1260
- — Z (S) $2100
1910.305 G01 IV A
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: (a) For employees exposed to potential electrical hazards where extensions cords are used as a permanent electrical source for lighting the work area on power press number 75 at 909 Fourth Avenue South, Wahpeton, North Dakota.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 332312)
YORK, PA—2026-07-10
AMERICAN SPECIALTY SYSTEMS INC.
YORK, PA—2026-07-10
AMERICAN SPECIALTY SYSTEMS INC.
CAMDEN, NJ—2026-07-08
CENTRAL METALS, INC.
SACRAMENTO, CA—2026-07-07
MARTIN'S STEEL WORKS, INC
LOUISVILLE, KY—2026-07-01
69275 - NORTH AMERICAN INDUSTRIAL SUPPLY INC
More inspections in ND
BEACH, ND—2026-07-09
NORED, INC.
BOWMAN, ND—2026-07-08
NORED, INC.
ELGIN, ND—2026-07-08
NORED, INC.
TIOGA, ND—2026-07-01
MUREX PETROLEUM CORPORATION
ARNEGARD, ND—2026-07-01
DEVON ENERGY CORPORATION
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337285415.