Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: KDA DEVELOPMENT CORPORATION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of KDA DEVELOPMENT CORPORATION in EASTERN VILLAGE RESIDENTIAL COMMUNITY END OF BALLENTINE DRIVE, SCARBOROUGH, ME 04070 (NAICS 236115). OSHA activity number 337309017.

Watch KDA Development Corporation — free Get an email when a new federal OSHA severe-injury report for KDA Development Corporation is published. One employer, no account, unsubscribe in one click.
Site address
EASTERN VILLAGE RESIDENTIAL COMMUNITY END OF BALLENTINE DRIVE
City
SCARBOROUGH
State
ME
ZIP
04070
Mailing
P.O. BOX 6799, SCARBOROUGH, ME 04070
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236115
Employees
3
Ownership type
A

6 citations on file for this inspection.

1903.19 C01

Deleted Other-than-serious 5 instances 10 exposed
Issued
Abate by
Penalty
Initial $400.00 · Current $0.00 Reduced
29 CFR 1903.19(c)(1):  Within 10 calendar days after the abatement date, the employer must certify to OSHA (the Agency) that each cited violation has been abated, except as provided in paragraph (c)(2) of this section.    At the jobsite - The employer did not furnish the abatement required for citations issued within 10 calendar days, nor did they respond to the progress report letter sent 01/22/2013 or the phone call on 02/19/2013.
Recent events (2)
  • — I (O) $0
  • — Z (O) $400

1926.304 F

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1000.00 Reduced
29 CFR 1926.304(f):     Section 4.1.2(a) American National Standards Institute 01.1-1961, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f): Circular hand-fed rip saws were not guarded by an automatically adjusting hood which completely enclosed that protion of the saw above the table and that protion of the saw above the material being cut:    Lot 85, First floor -  The controlling employer did not ensure that the Hitachi C10RB table saw used for ripping operations was provided with a guard covering the blade.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1926.304 F

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.304(f):     Section 4.1.2(b) American National Standards Institute 01.1-1961, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f): Circular hand-fed rip saws were not equipped with a spreader to prevent material from squeezing the saw blade:    Lot 85, First floor - The controlling employer did not ensure that the Hitachi C10RB table saw used for ripping operations was  provided with a spreader to prevent the material being cut from squeezing the saw blade.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.304 F

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.304(f):     Section 4.1.2(c) American National Standards Institute 01.1-1961, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f): Circular hand-fed rip saws did not have anti-kickback fingers or dogs to prevent the material from being thrown towards the operator:      Lot 85, First floor - The controlling employer did not ensure that the Hitachi C10RB table saw used for ripping operations was provided with anti-kickback fringers to prevent the material from being thrown towards the operator.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.404 B01 I

Serious Gravity 5 2 instances 3 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1000.00 Reduced
29 CFR 1926.404(b)(1)(i):     Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites:    The controlling employer did not ensure that ground fault circuit interrupters or an assured equipment grounding conductor program was used in the following instances:  a)  Lot 85, Second Floor - The painters plugged extension cords into a permanent wall receptacle to power portable 120 volt equipment.  b)  Lot 86, First Floor - The carpenter plugged an extension cord into a permanent wall receptacle to power a 120 volt DeWalt cut-off saw.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1926.1052 C01 I

Serious Gravity 1 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $600.00 Reduced
29 CFR 1926.1052(c)(1)(i):     Stairways having four or more risers or rising more than 30 inches, whichever is less, were not equipped with one stairrail system along each unprotected side or edge:    Lot 85, Front Entrance - The wooden stairway had five risers and was not equipped with one stairrail system along each unprotected side.
Recent events (2)
  • — I (S) $600
  • — Z (S) $1200

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337309017.