OSHA Inspection: JJJ BRASS & ALUMINUM FOUNDRY, LLC

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of JJJ BRASS & ALUMINUM FOUNDRY, LLC in 413 CLARK ST, SOUTH BELOIT, IL 61080 (NAICS 331529). OSHA activity number 337407217.

Watch JJJ Brass & Aluminum Foundry, LLC — free Get an email when a new federal OSHA severe-injury report for JJJ Brass & Aluminum Foundry, LLC is published. One employer, no account, unsubscribe in one click.
Site address
413 CLARK ST
City
SOUTH BELOIT
State
IL
ZIP
61080
Mailing
413 CLARK ST, SOUTH BELOIT, IL 61080
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331529
Employees
2
Ownership type
A

6 citations on file for this inspection.

1910.23 C01

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $2000.00 · Current $2000.00
29 CFR 1910.23(c)(1):     Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent):    (a)The employee operator of the mulling machine is exposed to a fall-to-ground hazard of approximately ten feet while standing on a metal platform.    Abatement documentation is not required, as this violation was corrected during the inspection.
Recent events (1)
  • — Z (S) $2000

1910.179 J02

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $2000.00
29 CFR 1910.179(j)(2):     The items listed in subparagraphs (j)(2)(i)-(vii) were not inspected for defects at intervals as defined in paragraph (j)(1)(ii) of this section or as specifically indicated, and all deficiencies were not carefully examined and a determination made as to whether they constituted a safety hazard:    (a) The employer did not complete frequent (monthly at minimum) inspections of its overhead P&H 623U Zip-Lift Hoist crane.    Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (1)
  • — Z (S) $2000

1910.179 J03

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.179(j)(3):     Complete inspections of the crane were not being performed at intervals as generally defined in paragraph (j)(1)(ii)(b) of this section:    (a) The employer did not complete periodic (yearly at minimum) inspections of its overhead P&H 623U Zip-Lift Hoist crane, exposing employees to permanent and disabling injuries as a result of spilled molten metal in the event of a crane failure.    Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (1)
  • — Z (S) $0

1910.303 B01 II

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $1600.00 · Current $1600.00
29 CFR 1910.303(b)(1)(ii):     Electrical equipment was not free from recognized hazards, based on the mechanical strength and durability, including, for parts designed to enclose and protect other equipment, the adequacy of the protection thus provided:    (a) Employees are exposed to electrical shock hazards from a missing knockout in the electrical panel located in the furnace area.    Abatement certification is required of this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (1)
  • — Z (S) $1600

1910.303 G01 VII

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(g)(1)(vii):     Switchboards, panelboards, and distribution boards installed for the control of light and power circuits, and motor control centers shall be located in dedicated spaces and protected from damage.    (a) Employees are exposed to electrical shock hazards from an electrical panel which is not protected from damage. It is missing a panel door.    Abatement certification is required of this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (1)
  • — Z (S) $0

1910.1200 E01

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(e)(1):     The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:    (a) The employer did not create a written hazard communication program for its employees to inform them of the hazards of the chemicals they are using including but not limited to silica.    Abatement certification is required of this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (1)
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337407217.