LAVONIA, GA —
OSHA Inspection: SHARK GLASS RECYCLING SE, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of SHARK GLASS RECYCLING SE, LLC in 1185 GERRARD RD., LAVONIA, GA 30553 (NAICS 423930). OSHA activity number 337462410.
Where did this inspection happen?
- Establishment
- SHARK GLASS RECYCLING SE, LLC
- Site address
- 1185 GERRARD RD.
- City
- LAVONIA
- State
- GA
- ZIP
- 30553
- Mailing
- 1185 GERRARD RD., LAVONIA, GA 30553
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423930
- Employees
- 2
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.242 B
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $960.00 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i. On or about November 2, 2012: (a) While performing cleaning operations employees were exposed to struck by hazards associated with cleaning nozzles being used not having effective chip guarding tips installed, air nozzles were producing more than 70 p.s.i out of nozzle tip.
Recent events (2)
- — I (S) $960
- — Z (S) $1600
1910.134 C01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use. On or about November 2, 2012: (a) Employees engaged in cleaning procedures were exposed to respiratory hazards when the employer required use of respirators but failed to implement and maintain a respiratory protection program to include training, fit test and medical evaluations.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.157 C01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries. On or about Novemebr 2, 2012: (a) Employees were exposed to burns and smoke inhalation hazards when a fire extinguisher located within the facility was blocked by materials awaiting further processing making fire extinguisher inaccessible to employees.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 423930)
OGDEN, UT—2026-07-10
TEAR A PART AUTO RECYCLING
GARNER, NC—2026-07-09
161490 - CAROLINA METAL RECYCLERS, LLC
JOPLIN, MO—2026-07-07
SERVICE RECYCLING - NORTH PLANT
HOLBROOK, NY—2026-07-01
ARROW SCRAP CORPORATION
DOVER, OH—2026-07-01
SPEEDIE AUTO SALVAGE
More inspections in GA