Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: JOSE VILLEGAS FRAMING

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JOSE VILLEGAS FRAMING in 400 PALUXY DRIVE, IRVING, TX 75039 (NAICS 236115). OSHA activity number 337482426.

Watch Jose Villegas Framing — free Get an email when a new federal OSHA severe-injury report for Jose Villegas Framing is published. One employer, no account, unsubscribe in one click.
Site address
400 PALUXY DRIVE
City
IRVING
State
TX
ZIP
75039
Mailing
1121 DUCK CREEK, GARLAND, TX 75041
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236115
Employees
9
Ownership type
A

3 citations on file for this inspection.

1926.102 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $2000.00
29 CFR 1926.102(a)(1): Employees were not provided with eye and face protection equipment when machines or operations present potential eye or face injury from physical, chemical, or radiation agents:    This violation occurred on November 20, 2012, at a workplace located at 400 Paluxy Drive, Irving, Texas; where employees used pneumatic nail guns andwere not protected from eye injuries by wearing protective eyewear.
Recent events (1)
  • — Z (S) $2000

1926.405 G01 II

Serious Gravity 10 1 instance 7 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.405(g)(1)(ii): When used as permitted in paragraphs (g)(1)(i)(C), (g)(1)(i)(F), or (g)(1)(i)(H) of 29 CFR 1926.405, the flexible cord was not equipped with an attachment plug and energized from a receptacle outlet:                                  This violation occurred on November 20, 2012, at a workplace located at 400 Paluxy Drive, Irving, Texas; where the employer inserted the conductors to Rolair compressor's flexible cord directly into a receptacle outlet exposing employees to electrical hazards.
Recent events (1)
  • — Z (S) $2800

1926.501 B13

Serious Gravity 10 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision in 29 CFR 1926.501(b), nor did the employer develop and implement a fall protection plan which met the requirements of paragraph (k) of 1926.502:    This violation occurred on November 20, 2012, at a workplace located at 400 Paluxy Drive, Irving, Texas; where employees were framing a two-story house and were not protected from falling to the lower levels.
Recent events (1)
  • — Z (S) $2800

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337482426.