MILFORD, CT —
OSHA Inspection: JOSE A. CALO RAMOS
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of JOSE A. CALO RAMOS in 25 KIRKSIDE AVENUE, MILFORD, CT 06460 (NAICS 238160). OSHA activity number 337502819.
Where did this inspection happen?
- Establishment
- JOSE A. CALO RAMOS
- Site address
- 25 KIRKSIDE AVENUE
- City
- MILFORD
- State
- CT
- ZIP
- 06460
- Mailing
- 2 CHARLES STREET APT 1, NORWALK, CT 06855
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 5
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.102 A01
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1400.00 Reduced
General-duty citation text
29 CFR 1926.102(a)(1): Employees shall be provided with eye and face protection equipment when machines or operations present potential eye or face injury from physical, chemical, or radiation agents. WORKSITE: The employee installing metal edging and roof underlayment using a pneumatic nail gun was not wearing eye protection.
Recent events (2)
- — I (S) $1400
- — Z (S) $2000
1926.501 B13
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $1960.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. WORKSITE: The employees walking and working on the following roofs without adequate fall protection system, exposing them to falls between 10-9 and 18-4 to the ground.
Recent events (2)
- — I (S) $1960
- — Z (S) $2800
1926.552 A01
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $1960.00 Reduced
General-duty citation text
29 CFR 1926.552(a)(1): The employer shall comply with the manufacturer's specifications and limitations applicable to the operation of all hoists and elevators. Where manufacturer's specifications are not available, the limitations assigned to the equipment shall be based on the determinations of a professional engineer competent in the field. WORKSITE: The employees were accessing the back side of the roof using the materials hoist in lieu of a ladder exposing the employees to falls up to 18'-4".
Recent events (2)
- — I (S) $1960
- — Z (S) $2800
1926.1053 B01
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1400.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support. WORKSITE: The side rails of the bottom half of a Werner model D30028, 28 foot aluminum extension ladder, used by employees to access the roof did not extend at least three (3) feet above the roof eave and the ladder was not secured to prevent accidental displacement.
Recent events (2)
- — I (S) $1400
- — Z (S) $2000
1926.1053 B05 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1053(b)(5)(i): Non-self-supporting ladders shall be used at an angle such that the horizontal distance from the top support to the foot of the ladder is approximately one-quarter of the working length of the ladder (the distance along the ladder between the foot and the top support). WORKSITE: The bottom half of a Werner model D30028, 28 foot aluminum extension ladder, used by employees to access the roof was setup at an angle where the horizontal distance from the top support to the foot of the ladder exceeded one-quarter(1/4) of the working length of the ladder.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 238160)
FAIRVIEW, TN—2026-07-16
MARVIN PINERA
CARSON CITY, NV—2026-07-16
UNKNOWN/INVALID ESTABLISHMENT
BANNOCKBURN, IL—2026-07-16
ROOFING H.P. LLC
LOXLEY, AL—2026-07-16
CARLOS CHE
BALTIMORE, MD—2026-07-16
VAL CONSTRUCTION INC
More inspections in CT
ENFIELD, CT—2026-07-16
MOMS ENFIELD
DAYVILLE, CT—2026-07-16
HARBOR FREIGHT
NEW BRITAIN, CT—2026-07-14
JANANII, LLC
NEWINGTON, CT—2026-07-14
TRUSS MANUFACTURING INC
NORTH BRANFORD, CT—2026-07-14
NYK STATEWIDE MOLINA CONSTRUCTION LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337502819.