Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: WIGLEY CONTRACTING

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of WIGLEY CONTRACTING in FIRST PRESBYTERIAN CHURCH 369 WARREN STREET, HUDSON, NY 12534 (NAICS 238130). OSHA activity number 337510218.

Watch Wigley Contracting — free Get an email when a new federal OSHA severe-injury report for Wigley Contracting is published. One employer, no account, unsubscribe in one click.
Establishment
WIGLEY CONTRACTING
Site address
FIRST PRESBYTERIAN CHURCH 369 WARREN STREET
City
HUDSON
State
NY
ZIP
12534
Mailing
P.O. BOX 160, PHILMONT, NY 12565
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
2
Ownership type
A

5 citations on file for this inspection.

1926.404 B01 I

Deleted Serious Gravity 1 1 instance 2 exposed
Issued
Penalty
Initial $1020.00 · Current $0.00 Reduced
29 CFR 1926.404(b)(1)(i):  Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites:    (a) Front of Building - on or about November 21, 2012 - employees were using electric tools that were not protected by a Ground Fault Circuit Interrupter.
Recent events (3)
  • — F (S) $0
  • — C (S) $1020
  • — Z (S) $1020

1926.404 A02

Deleted Serious Gravity 1 1 instance 2 exposed
Issued
Penalty
Initial $1020.00 · Current $0.00 Reduced
29 CFR 1926.404(a)(2):  A grounded conductor was attached to a terminal or lead so as to reverse designated polarity    (a) Front of Building - on or about November 21, 2012 - employees were using electric tools that were connected to an outlet that was wired in reverse polarity.
Recent events (3)
  • — F (S) $0
  • — C (S) $1020
  • — Z (S) $1020

1926.405 A02 II I

Deleted Serious Gravity 1 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.405(a)(2)(ii)(I):  Protection was not provided to avoid damage to flexible cords and cables used for temporary wiring which passed through doorways or other pinch points:    (a) Front of Building - on or about November 21, 2012 - the extension cord that was supplying power to the electric tools was pinched in the front doorway.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1926.453 B02 V

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $1700.00 · Current $0.00 Reduced
29 CFR 1926.453(b)(2)(v):  A body belt was not worn and/or a lanyard was not attached to the boom or basket when working from an aerial lift:      (a) Front of Building, on or about November 21, 2012 - an employee was performing work from an extensible boom man lift without wearing a body harness or a body belt.
Recent events (3)
  • — F (S) $0
  • — C (S) $1700
  • — Z (S) $1700

1926.454 A

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.454(a):  The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards:    (a) Front of Building, on or about November 21, 2012 - the employer did not provide fall protection training to the employee that was performing work from an extensible boom man lift.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337510218.