PHILADELPHIA, PA —
OSHA Inspection: SETAG MASONRY
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SETAG MASONRY in 1845 FITZWATER ST, PHILADELPHIA, PA 19146 (NAICS 238140). OSHA activity number 337526826.
Where did this inspection happen?
- Establishment
- SETAG MASONRY
- Site address
- 1845 FITZWATER ST
- City
- PHILADELPHIA
- State
- PA
- ZIP
- 19146
- Mailing
- 1670 SHEFLEY LANE, COLLEGEVILLE, PA 19426
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 12
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.451 C01
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1300.00 Reduced
General-duty citation text
29 CFR 1926.451(c)(1): Supported scaffolds with a height to base width (including outrigger supports, if used) ratio of more than four to one (4:1) were not restrained from tipping by guying, tying, bracing, or equivalent means. a) Jobsite: 1845 Fitzwater St, Philadelphia, PA - On or about 11/26/12, the supported tubular welded frame scaffold, measuring approximately 33 feet in elevation and 5 feet in width, was not restrained from tipping or falling over by guying, tying, bracing, or equivalent means. Employees were performing masonry operations from the 4th working platform approximately 27 feet above ground level, and from the outrigger section, approximately 30 feet above ground level.
Recent events (2)
- — I (S) $1300
- — Z (S) $2000
1926.451 C02
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1820.00 Reduced
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates, mud sills or other adequate firm foundation: a) Jobsite: 1845 Fitzwater St, Philadelphia, PA - On or about 11/26/12, the supported tubular welded frame scaffold was at risk of collapsing or shifting because the legs did not bear on an adequate firm foundation, but on planks 2 and 3 feet above the window wells. Employees were performing masonry operations from the 4th working platform approximately 27 feet above ground level, and from the outrigger section, approximately 30 feet above ground level.
Recent events (2)
- — I (S) $1820
- — Z (S) $2000
1926.451 G01 VII
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $1300.00 Reduced
General-duty citation text
29 CFR 1926.451(g)(1)(vii): For all scaffolds not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, each employee was not protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. a) Jobsite: 1845 Fitzwater St, Philadelphia, PA - On or about 11/26/12, employees were not provided with a fall protection system while working from the outrigger and platform sections of the supported tubular welded frame scaffold. Employees performing masonry operations from the outrigger section of the scaffold were exposed to fall hazards approximately 30 feet above ground level, and approximately 27 feet above ground level from the 4th working platform.
Recent events (2)
- — I (S) $1300
- — Z (S) $2800
1926.501 B04 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.501(b)(4)(ii): Each employee on a walking/working surface was not protected from tripping in or stepping into or through holes by covers. a) Jobsite: 1845 Fitzwater St, Philadelphia, PA - On or about 11/26/12, the window well holes beneath and immediately to the right of the supported tubular welded frame scaffold were not covered or guarded to prevent employees from tripping in or stepping into the holes. The holes measured 3 feet and 4 feet deep.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 H01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: a) Jobsite: 1845 Fitzwater St, Philadelphia, PA - On or about 11/26/12, Setag Construction did not provide their employees with effective information and training on the hazardous chemical Dark Masonry Cement at their work area.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 238140)
RENO, NV—2026-07-16
DC MASONRY
WINNETKA, IL—2026-07-15
CHICAGO STUCCO CO.
LODI, NJ—2026-07-15
J & O MASONRY CONTRACTORS
DORAVILLE, GA—2026-07-14
SUDLOW CONCRETE, INC.
FLAGLER BEACH, FL—2026-07-14
PLANET DESIGN SERVICES, INC.
More inspections in PA
PHILADELPHIA, PA—2026-07-16
URUS CONSTRUCTION CORPORATION
JEFFERSON HILLS, PA—2026-07-16
MARATHON PETROLEUM COMPANY ASPHALT TERMINAL
SMITHFIELD, PA—2026-07-16
CARLISLE CONSTRUCTION MATERIALS
PITTSBURGH, PA—2026-07-15
DREAM GREENER LAWN & LANDSCAPE
COCHRANTON, PA—2026-07-15
CRAWFORD COUNTY HARDWOODS, LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337526826.