Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: CENTRAL INDUSTRIAL PACKAGING & SUPPLY II, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CENTRAL INDUSTRIAL PACKAGING & SUPPLY II, INC. in 8255 WILLETT PARKWAY, BALDWINSVILLE, NY 13027 (NAICS 322211). OSHA activity number 337568422.

Watch Central Industrial Packaging & Supply II, INC. — free Get an email when a new federal OSHA severe-injury report for Central Industrial Packaging & Supply II, INC. is published. One employer, no account, unsubscribe in one click.
Site address
8255 WILLETT PARKWAY
City
BALDWINSVILLE
State
NY
ZIP
13027
Mailing
P.O. BOX 164, BALDWINSVILLE, NY 13027
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
322211
Employees
14
Ownership type
A

13 citations on file for this inspection.

1910.23 C01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1360.00 · Current $884.00 Reduced
29 CFR 1910.23(c)(1):     Open-sided floor(s) or platform(s) 4 feet or more above the adjacent floor or ground level were not guarded by standard railings (or the equivalent as specified in 29 CFR 1910.23(e)(3)(i) through (v)), on all open sides:    a)  In the warehouse, on or about 11/28/12:  An overhead storage area approximately 10 feet from floor level was not provided with standard guardrails.    Abatement certification must be submitted for this item.
Recent events (2)
  • — I (S) $884
  • — Z (S) $1360

1910.147 C01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1700.00 · Current $1105.00 Reduced
29 CFR 1910.147(c)(1):     The employer did not establish an energy control program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected enegizing, start up or release of stored energy could occur and cause injury, the machine or equipment would be isolated, and rendered inoperative:      a)  At the establishment, on or about 11/28/12:  Where employees perform servicing and/or maintenance on various machinery and equipment, including, but not limited to scoring/slitting machines, saws, air compressor, etc., the employer had not established a lockout/tagout program which included written energy control procedures, training of all authorized and affected employees and periodic inspections, to prevent the unexpected energizing, start up or release of stored energy of the equipment.    Abatement certification must be submitted for this item.
Recent events (2)
  • — I (S) $1105
  • — Z (S) $1700

1910.212 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1700.00 · Current $1105.00 Reduced
29 CFR 1910.212(a)(1):     Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by rotating parts:    a)  Manufacturing Area, on or about 11/28/12:  Rotating chuck on a Sears Craftsman drill press was not guarded.    Abatement certification must be submitted for this item.
Recent events (2)
  • — I (S) $1105
  • — Z (S) $1700

1910.212 A03 II

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.212(a)(3)(ii):     Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):    a)  Manufacturing Area, on or about 11/28/12:  Point of operation on a S&S slitter/scorer machine was not guarded.    Abatement certification must be submitted for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.219 D01

Serious Gravity 5 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $1360.00 · Current $884.00 Reduced
29 CFR 1910.219(d)(1):     Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):    a)  Main Dock Area, Shipping/Receiving, on or about 11/28/12:  Pulleys driving a Seal Tech bandsaw were not guarded.    b)  Manufacturing Area, on or about 11/28/12:  Pulleys driving a Sears Craftsman table saw were not guarded.    Abatement certification must be submitted for these items.
Recent events (2)
  • — I (S) $884
  • — Z (S) $1360

1910.219 E03 I

Serious Gravity 5 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.219(e)(3)(i):     Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o):    a)  Main Dock Area, Shipping/Receiving, on or about 11/28/12:  V belt driving the Seal Tech bandsaw was not guarded.    b)  Manufacturing Area, on or about 11/28/12:  V belt driving a Sears Craftsman table saw was not guarded.    Abatement certification must be submitted for these items.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 B02

Serious Gravity 1 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $1020.00 · Current $663.00 Reduced
29 CFR 1910.303(b)(2):     Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    a)  Repair Room, on or about 11/28/12:  A strip outlet used to power vacuum cleaners was permanently attached to the wall and supplying power to vacuum cleaners which was not in accordance with the listing or labeling.    b)  Manufacturing Area, on or about 11/28/12:  A strip outlet on a workbench providing current to glue guns was not in accordance with the listing or labeling.    Abatement certification must be submitted for these items.
Recent events (2)
  • — I (S) $663
  • — Z (S) $1020

1910.305 G01 IV A

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(1)(iv)(A):     Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:    a)  Main Dock Area/Shipping and Receiving, on or about 11/28/12:  An orange extension cord providing current to a Seal Tech bandsaw was strung across the floor and being used as permanent wiring.    Abatement certification must be submitted for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G02 III

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(2)(iii):     Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:    a)  Maintenance Dock Area, Shipping/Receiving, on or about 11/28/12:  There was no strain relief on an orange extension cord providing current to a Seal Tech bandsaw, in that the cord was pulled loose from the plug fitting.    Abatement certification must be submitted for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.304 G05

Serious Gravity 1 2 instances 1 exposed
Issued
Abate by
Penalty
Initial $1020.00 · Current $663.00 Reduced
29 CFR 1910.304(g)(5):     The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:    a)  Manufacturing Area, on or about 11/28/12:  A Delta bandsaw and a Craftsman radial arm saw were not grounded in that the ground pins were missing from the plug ends.    Abatement certification must be submitted for this item.
Recent events (2)
  • — I (S) $663
  • — Z (S) $1020

1910.305 B01 I

Serious Gravity 1 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(b)(1)(i):     Conductors entering boxes, cabinets, or fittings were not protected from abrasions and openings through which condutors entered boxes, cabinets or fittings were not effectively closed:    a)  Main Dock Area, Shipping/Receiving, on or about 11/28/12:  Junction box for the wrapping table foot pedal was pulled loose from fitting and a knockout was missing on the junction box.    b)  Manufacturing Area, on or about 11/28/12:  Flexible conduit providing current to the foot pedal for the Bostitch stitcher was pulled loose at the fitting and the ground wire was disconnected.    Abatement certification must be submitted for these items.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.37 B02

Other-than-serious 2 instances 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.37(b)(2):     Each exit was not clearly visible and marked by a sign reading "Exit":    a)  Back Warehouse Room, on or about 11/28/12:  Door used as an exit was not marked with an exit sign.    b)  Jan/San Warehouse, on or about 11/28/12:  Door used as an exit was not marked with an exit sign.    Abatement certification must be submitted for these items.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 E01

Other-than-serious 1 instance 12 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(e)(1):     The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:    a)  At the establishment, on or about 11/28/12:  There was no written hazard communication program or employee training for employees using and/or exposed to various janitorial cleaning supplies, bowl cleaner, drain cleaner, along with glues, oils, propane, etc.    Abatement certification must be submitted for this item.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337568422.