NEW LONDON, WI —
OSHA Inspection: PERFECSEAL - NEW LONDON
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PERFECSEAL - NEW LONDON in 755 INDUSTRIAL LOOP ROAD, NEW LONDON, WI 54961 (NAICS 326112). OSHA activity number 337580617.
Where did this inspection happen?
- Establishment
- PERFECSEAL - NEW LONDON
- Site address
- 755 INDUSTRIAL LOOP ROAD
- City
- NEW LONDON
- State
- WI
- ZIP
- 54961
- Mailing
- 755 INDUSTRIAL LOOP ROAD, NEW LONDON, WI 54961
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326112
- Employees
- 100
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.23 C01
- Issued
- Abate by
- Penalty
- Initial $4250.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.23(c)(1): Open sided floor(s) or platform(s) 4 feet or more above the adjacent floor or ground level were not guarded by standard railings (or the equivalent as specified in 29 CFR 1910.23(3)(3)(i) through (v)), on all open sides: a) Employee threading foil from 12" x 12" beam approximately 65" off the floor on unwind #2 without fall protection. ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
- — I (O) $0
- — Z (S) $4250
1910.132 D01 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.132(d)(1)(i): The employer did not select and have each affected employee use the types of personal protective equipment that would protect the affected employee(s) from the hazards identified in the hazard assessment: a) Employee threading foil from 12" x 12" beam approximately 65" off the floor on unwind #2 without fall protection. ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A01
- Issued
- Abate by
- Penalty
- Initial $2550.00 · Current $1275.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Jet horizontal metal bandsaw in maintenance shop did not have the unused portion of the blade guarded. ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
- — I (S) $1275
- — Z (S) $2550
1910.305 G01 IV A
- Issued
- Abate by
- Penalty
- Initial $3400.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a) Flexible cord was being used to supply power to a Jet horizontal metal saw in the Maintenance Shop. ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
- — I (O) $1000
- — Z (S) $3400
1910.303 B01 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.303(b)(1)(ii): Electrical equipment was not free from recognized hazards, based on the mechanical strength and durability, including, for parts designed to enclose and protect other equipment, the adequacy of the protection thus provided: a) Extension cord supplying power to camera system had a molded plug with the wiring pulled loose. ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 326112)
SUWANEE, GA—2026-06-25
ROSSINI NORTH AMERICA, LLC
ORANGEBURG, SC—2026-06-17
77529 - INDEVCO INC OF NORTH AMERICA
CONOVER, NC—2026-05-13
161214 - PREGIS PROTECTIVE FILMS - COATINGS, INC.
BIOLA, CA—2026-05-07
POLYCELL PACKAGING CORPORATION
RHINELANDER, WI—2026-05-06
PRINTPACK INC.
More inspections in WI
MUSCODA, WI—2026-07-10
SCOT INDUSTRIES, INC
FRANKLIN, WI—2026-07-10
EDGE BROADBAND SOLUTIONS LLC
APPLETON, WI—2026-07-10
LAWRENCE UNIVERSITY OF WISCONSIN
KIMBERLY, WI—2026-07-10
ENRIQUE RESENDIC
SLINGER, WI—2026-07-10
DYLAN MATTHEW SHELLEY LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337580617.