Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: NEW HOUSE CARPENTRY

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of NEW HOUSE CARPENTRY in 276 BUTTONWOOD AVE, CORTLANDT MANOR, NY 10567 (NAICS 238350). OSHA activity number 337645824.

Watch NEW House Carpentry — free Get an email when a new federal OSHA severe-injury report for NEW House Carpentry is published. One employer, no account, unsubscribe in one click.
Establishment
NEW HOUSE CARPENTRY
Site address
276 BUTTONWOOD AVE
City
CORTLANDT MANOR
State
NY
ZIP
10567
Mailing
16 TOWER PLACE 2ND FLOOR, DANBURY, CT 06810
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238350
Employees
3
Ownership type
A

8 citations on file for this inspection.

1903.19 C01

Other-than-serious 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $400.00 · Current $400.00
29 CFR 1903.19(c)(1): Within 10 calendar days after the abatement date, the employer did not certify to OSHA (the Agency) that each cited violation has been abated, except as provided in paragraph (c)(2) of this section.     a )  The employer did not provide this office certification that items 1 and 5b of citation 1 have been corrected.  Abatement note: To abate this citation, the employer's certification that abatement is complete must include, for each cited violation, in addition to the information required by paragraph (h) of this section, the date and method of abatement and a statement that affected employees and their representatives have been informed of the abatement.
Recent events (1)
  • — Z (O) $400

1926.404 B01 I

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $2000.00
29 CFR 1926.404(b)(1)(i): The employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites:    Location: 276 Buttonwood Ave Cortlandt Manor NY 10567    On or about 11/29/12,  a) Employees that used electrical tools including a Bosch miter saw and Dewalt reciprocating saw powered by a 6000 watt generator were not protected by either a ground fault circuit interrupter or an assured equipment grounding conductor program.
Recent events (1)
  • — Z (S) $2000

1926.451 G01 VII

Serious Gravity 10 2 instances 3 exposed
Issued
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section:    Location: 276 Buttonwood Ave Cortlandt Manor NY 10567    On or about 11/29/12,  a) Employees working from a pump jack scaffold and a roof bracket scaffold were not protected from falling to the ground below.
Recent events (1)
  • — Z (S) $2800

1926.451 B05 I

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $2000.00 · Current $2000.00
29 CFR 1926.451(b)(5)(i): The end of a platform 10 feet or less in length extended over its support more than 12 inches and the platform was not designed and installed so that the cantilevered portion of the platform is able to support employees and/or materials without tipping, or has guardrails which block employee access to the cantilivered end:    Location: 276 Buttonwood Ave Cortlandt Manor NY 10567    On or about 11/29/12,  a) A scaffold plank on a roof bracket scaffold extended approximately 15 inches beyond its end support. It was not installed so that the cantilevered portion of the platform was able to support an employee without tipping.
Recent events (1)
  • — Z (S) $2000

1926.452 J02

Serious Gravity 5 2 instances 3 exposed
Issued
Penalty
Initial $2000.00 · Current $2000.00
29 CFR 1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary:    Location: 276 Buttonwood Ave Cortlandt Manor NY 10567    On or about 11/29/12,  a) Poles for a pump jack scaffold were not secured at the bottom.
Recent events (1)
  • — Z (S) $2000

1926.501 B13

Serious Gravity 10 3 instances 3 exposed
Issued
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by a guardrail system, safety net system, or personal fall arrest system:    Location: 276 Buttonwood Ave Cortlandt Manor NY 10567    On or about 11/29/12,  a) Employees accessing a roof with a 12 in 12 pitch to perform siding work were not protected from falling to the ground below.
Recent events (1)
  • — Z (S) $2800

1926.21 B02

Serious Gravity 10 3 instances 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury:    Location: 276 Buttonwood Ave Cortlandt Manor NY 10567    On or about 11/29/12,  a) The employer did not adequately train employees to recognize hazards and applicable regulations to control or eliminate those hazards related to fall protection, scaffolding, ladders and working wiith electrical equipment.
Recent events (1)
  • — Z (S) $0

1926.1053 B05 I

Serious Gravity 5 2 instances 3 exposed
Issued
Penalty
Initial $2000.00 · Current $2000.00
29 CFR 1926.1053(b)(5)(i): Non-self-supporting ladder(s) were not used at an angle such that the horizontal distance from the top support to the foot of the ladder was approximately one-quarter of the working length of the ladder:    Location: 276 Buttonwood Ave Cortlandt Manor NY 10567    On or about 11/29/12,  a) Two extension ladders used in conjunction with pump jack scaffolding were set up at angles that were too shallow.
Recent events (1)
  • — Z (S) $2000

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337645824.