OSHA Inspection: GROSS & JANES CO.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of GROSS & JANES CO. in HWY A & 49, WILLIAMSVILLE, MO 63967 (NAICS 321999). OSHA activity number 337668016.

Watch Gross & Janes CO. — free Get an email when a new federal OSHA severe-injury report for Gross & Janes CO. is published. One employer, no account, unsubscribe in one click.
Establishment
GROSS & JANES CO.
Site address
HWY A & 49
City
WILLIAMSVILLE
State
MO
ZIP
63967
Mailing
P.O. BOX 125, WILLIAMSVILLE, MO 63967
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321999
Employees
12
Ownership type
A

7 citations on file for this inspection.

1910.23 C01

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $840.00 Reduced
29 CFR 1910.23(c)(1):     Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards: (Note:  Toeboards are only required when persons can pass, there is moving equipment or there is equipment with which falling materials could create a hazard.)    a. Guardrails were not provided at all openings on the end plate platform (62" fall potential).    Abatement certification and abatement documentation is required for this violation.  The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful.  The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
  • — I (S) $840
  • — Z (S) $1200

1910.147 C01

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1400.00 Reduced
29 CFR 1910.147(c)(1):     The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:    a. No formal lockout program was established, including no written program and specific operating procedures, no documented training of authorized or affected employees, and equipment was maintained, such as adjustment and changing of saws, without locking out the equipment.    Abatement certification and abatement documentation is required for this violation.  The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful.  The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2000

1910.212 A03 II

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1400.00 Reduced
29 CFR 1910.212(a)(3)(ii):     Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):    a. Incising rollers were not guarded.    Abatement certification and abatement documentation is required for this violation.  The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful.  The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2000

1910.213 F01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.213(f)(1):     Feed rolls and saws on self-feed circular saw(s) were not protected by a hood or guard to prevent the hands of the operator from coming in contact with the in-running rolls:    a. kurf saws were not guarded.    Abatement certification and abatement documentation is required for this violation.  The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful.  The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.219 D01

Serious Gravity 5 2 instances 4 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1400.00 Reduced
29 CFR 1910.219(d)(1):     Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):    a. The Ingersoll Rand compressor belt and pulley were not guarded.    b. The motor belt and pulley to the south line trim saws were not guarded.    Abatement certification and abatement documentation is required for this violation.  The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful.  The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2000

1910.219 F03

Serious 3 instances 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.219(f)(3):     Sprocket wheels and chains which were seven (7) feet or less above floors or platforms were not enclosed:    a. Chain and sprocket at the south end drive chain was not guarded.    b. Chain and sprocket at end of kurf saw line was not guarded.    c. Chain and sprocket at the tie transfer conveyor was not guarded.    Abatement certification and abatement documentation is required for this violation.  The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful.  The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 G02 I

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $840.00 Reduced
29 CFR 1910.303(g)(2)(i):     Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):    a. The Ingersoll Rand compressor control box cover was removed exposing electrical contacts.    Abatement certification and abatement documentation is required for this violation.  The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful.  The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
  • — I (S) $840
  • — Z (S) $1200