SMYRNA, GA —
OSHA Inspection: JULIO CESAR RICO
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of JULIO CESAR RICO in LOT #20 CENTRAL GARDEN COURT, SMYRNA, GA 30080 (NAICS 238130). OSHA activity number 337671432.
Where did this inspection happen?
- Establishment
- JULIO CESAR RICO
- Site address
- LOT #20 CENTRAL GARDEN COURT
- City
- SMYRNA
- State
- GA
- ZIP
- 30080
- Mailing
- 2758 ARUBA DRIVE, POWDER SPRINGS, GA 30127
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 3
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.102 A01
- Issued
- Penalty
- Initial $1600.00 · Current $480.00 Reduced
General-duty citation text
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents. (a) Residential roof located at Lot#20, Cental Garden Court, Smyrna, GA 30080: Employees were not protected from eye injuries while installing sheathing with pneumatic Hitachi (Model-NR83A2) Stick Framing Nail Guns as these tools were operated without safety glasses.
Recent events (2)
- — I (S) $480
- — Z (S) $1600
1926.501 B13
- Issued
- Penalty
- Initial $2800.00 · Current $840.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501 (b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502: (a) Residential roof located at Lot #20, Central Garden Court, Smyrna, GA 30080: Employees were exposed to fall hazards of approximately 21'7" to the ground while installing sheathing on a 6/12 pitched roof with no fall protection system in place.
Recent events (2)
- — I (S) $840
- — Z (S) $2800
More inspections in this industry (NAICS 238130)
FAIRHOPE, AL—2026-07-16
FRANCISCO ARES
WOODHAVEN, MI—2026-07-16
G.J. PERELLI CO., L.L.C.
PHILADELPHIA, PA—2026-07-16
URUS CONSTRUCTION CORPORATION
BERLIN, NJ—2026-07-16
URUS CONSTRUCTION CORPORATION
MERIDIAN, ID—2026-07-15
TRIPLE R CONSTRUCTION LLC
More inspections in GA
GREENSBORO, GA—2026-07-16
PURE BEAUTY FARMS, INC.
FOREST PARK, GA—2026-07-16
POLYNT COMPOSITES USA INC.
AUGUSTA, GA—2026-07-16
GF CASTING SOLUTIONS AUGUSTA, LLC
CHAMBLEE, GA—2026-07-16
U.S. DEPARTMENT OF TREASURY
DECATUR, GA—2026-07-15
PALLETS ACQUISITION LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337671432.