Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: THAYER'S Y-KNOT BOATYARD, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of THAYER'S Y-KNOT BOATYARD, INC. in 352 MAIN STREET, NORTH HAVEN, ME 04853 (NAICS 336612). OSHA activity number 337674014.

Watch Thayer'S Y-Knot Boatyard, INC. — free Get an email when a new federal OSHA severe-injury report for Thayer'S Y-Knot Boatyard, INC. is published. One employer, no account, unsubscribe in one click.
Site address
352 MAIN STREET
City
NORTH HAVEN
State
ME
ZIP
04853
Mailing
352 MAIN STREET, NORTH HAVEN, ME 04853
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336612
Employees
4
Ownership type
A

3 citations on file for this inspection.

1910.213 B03

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1700.00 · Current $0.00 Reduced
29 CFR 1910.213(b)(3):   On applications where injury to the operator might result if motors were to restart after power failures, provision shall be made to prevent machines from automatically restarting upon restoration of power.      Wood Shop - The Powermatic Model #66 tablesaw did not have an anti-restart safety device.
Recent events (2)
  • — I (S) $0
  • — Z (S) $1700

1910.37 B02

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.37(b)(2): Each exit must be clearly visible and marked by a sign reading "Exit."      Main Office - An exit sign was not placed over the entrance door.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.335 B01

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.335(b)(1): Safety signs and tags. Safety signs, safety symbols, or accident prevention tags shall be used where necessary to warn employees about electrical hazards which may endanger them, as required by 1910.145.      Outboard Shop - An electrical breaker panel that was installed on or about August of 2012 did not have an "Arc Flash Hazard" warning sign on the front of the panel box.