OSHA Inspection: CAINS FOODS, LP

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of CAINS FOODS, LP in 114 EAST MAIN ST., AYER, MA 01432 (NAICS 311941). OSHA activity number 337688824.

Watch Cains Foods, LP — free Get an email when a new federal OSHA severe-injury report for Cains Foods, LP is published. One employer, no account, unsubscribe in one click.
Establishment
CAINS FOODS, LP
Site address
114 EAST MAIN ST.
City
AYER
State
MA
ZIP
01432
Mailing
114 EAST MAIN ST., AYER, MA 01432
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311941
Employees
143
Ownership type
A

8 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $3825.00 · Current $3479.00 Reduced
OSH ACT of 1970 Section (5)(a)(1):  The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to crushing hazards:    (a)  Location - Warehouse:  On or about 12/18/12 multiple storage racks, holding pallets of mayonaisse and/or dressing product with an average weight of 1850 pounds each, had structural damage exposing employees to hazards of being struck or crushed by falling pallets and boxes.
Recent events (2)
  • — I (S) $3479
  • — Z (S) $3825

1910.22 D01

Other-than-serious 2 instances 10 exposed
Issued
Abate by
Penalty
Initial $3825.00 · Current $500.00 Reduced
29 CFR 1910.22(d)(1):  On every building or other structure, or part thereof, used for mercantile, business, industrial or storage purposes, the loads approved by the building official were not marked on plates of approved design and securely affixed in a conspicuous place in each space to which they relate:    (a)  Location -  Main Building, Loading Dock  On or about 12/5/2012, the load rating for the storage racks located above the loading dock overhead doors was not posted.  The storage racks held pallets of rolled labels.    (b)  Location - Warehouse  On or about 12/18/2012, the load rating for the storage racks was not posted. The storage racks held pallets of mayonaisse and dressings in boxes.
Recent events (2)
  • — I (O) $500
  • — Z (S) $3825

1910.147 C06 I

Serious Gravity 5 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $3825.00 · Current $3479.00 Reduced
29 CFR 1910.147(c)(6)(i):  The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed:    (a)  Location - Establishment  On or about 12/5/2012, the employer did not conduct an annual or more frequent inspection of the Lock Out Tag Out procedures to ensure the procedures and energy control requirements were followed when cleaning, maintaining or repairing the plant equipment including, but not limited to, mixers, bottlers, and conveyors.
Recent events (2)
  • — I (S) $3479
  • — Z (S) $3825

1910.303 C03 I

Other-than-serious 3 instances 50 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(c)(3)(i):  Conductors shall be spliced or joined with splicing devices identified for the use or by brazing, welding, or soldering with a fusible metal or alloy. Soldered splices shall first be spliced or joined to be mechanically and electrically secure without solder and then soldered. All splices and joints and the free ends of conductors shall be covered with an insulation equivalent to that of the conductors or with an insulating device identified for the purpose:    (a)  Location - Production Area  On or about 12/5/12 an electrical cord, servicing the boxing machine, was repaired with black electrical tape.    (b)  Location - Forklift Charging Area  On or about 12/5/12 an electrical cord, servicing a powered industrial truck charger, was repaired with yellow electrical tape.    (c)  Location - Forklift Charging Area  On or about 12/5/12 an electrical cord, servicing a powered industrial truck charger, was repaired with black electrical tape.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.303 G01

Serious Gravity 5 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(g)(1):     Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:    (a)  Main Plant, Forklift Charging Station  On or about 12/5/12 an electrical panel box was blocked by a forklift charger.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G01 IV

Serious Gravity 5 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(1)(iv):      Flexible cords and/ or cables were used for purposes prohibited by paragraphs (A) through (F) of 29 CFR 1910.305(g)(1)(iv):    (a)  Location - Warehouse    On or about 12/5/12, an electrical cord powering a water cooler was run under a door to an outlet on the other side of the wall.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G02 III

Serious Gravity 5 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(2)(iii):  Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:    (a)  Location - Establishment:  On or about 12/5/12 an electrical cord, powering a box machine, had exposed wire between the plug and cord where a strain relief had not been provided.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 K06

Other-than-serious 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $765.00 · Current $765.00
29 CFR 1910.134(k)(6):  The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, in written or oral format to employees who wear respirators when such use was not required by the employer:    (a)  Location - Establishment  On or about 12/5/12 the employer did not provide the information in Appendix D of 1910.134 to employees that were allowed to wear tight-fitting filtering facepiece respirators.
Recent events (2)
  • — I (O) $765
  • — Z (O) $765

View CAINS FOODS, LP's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337688824.