ORLANDO, FL —
OSHA Inspection: TOP LINE SCREEN PRINTING AND EMBROIDERY, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of TOP LINE SCREEN PRINTING AND EMBROIDERY, INC. in 4210 L.B. MCLEOD ROAD, #109, ORLANDO, FL 32811 (NAICS 323113). OSHA activity number 337691018.
Where did this inspection happen?
- Establishment
- TOP LINE SCREEN PRINTING AND EMBROIDERY, INC.
- Site address
- 4210 L.B. MCLEOD ROAD, #109
- City
- ORLANDO
- State
- FL
- ZIP
- 32811
- Mailing
- 4210 L.B. MCLEOD ROAD, #109, ORLANDO, FL 32811
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 323113
- Employees
- 83
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.36 D01
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $1680.00 Reduced
General-duty citation text
29 CFR 1910.36(d)(1): Employee(s) were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge: a) Southeast Corner of Building - The door was equipped with a deadbolt and a gate that was fastened with a carabineer that was not easily removed, on or about December 5, 2012.
Recent events (2)
- — I (S) $1680
- — Z (S) $2800
1910.95 C01
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $1680.00 Reduced
8111
General-duty citation text
29 CFR 1910.95(c)(1): The employer did not administer a continuing, effective hearing conservation program as described in 29 CFR 1910.9(c) through (o) whenever employee noise exposures equal or exceed an 8-hour time-weighted average sound level of 85 decibels measured on the A scale, or equivalently a dose of fifty percent: a) Screening Area - No program was in place and an employee was exposed during the 408 minute monitoring period to 90.1 percent of the allowable daily exposure, on or about December 13, 2012. This dose is equivalent to 90 dBA.
Recent events (2)
- — I (S) $1680
- — Z (S) $2800
1910.213 C01
- Issued
- Penalty
- Initial $3500.00 · Current $2100.00 Reduced
General-duty citation text
29 CFR 1910.213(c)(1): Circular handfed ripsaw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut: a) Maintenance Area - Ryobi 10 inch table saw, model BTS12S, serial number XX094099024, on or about December 5, 2012.
Recent events (2)
- — I (S) $2100
- — Z (S) $3500
1910.213 C02
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.213(c)(2): Hand-fed circular ripsaw(s) were not furnished with a spreader to prevent material from squeezing the saw or being thrown back on the operator: a) Maintenance Area - Ryobi 10 inch table saw, model BTS12S, serial number XX094099024, on or about December 5, 2012.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.213 C03
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.213(c)(3): Hand-fed ripsaw(s) did not have non-kickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator: a) Maintenance Area - Ryobi 10 inch table saw, model BTS12S, serial number XX094099024, on or about December 5, 2012.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C07 IV
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(7)(iv): The employer had not certified that employee training had been accomplished and kept up to date: a) Facility-wide - There was no certification for affected employees, on or about December 13, 2012.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 B02 I
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: a) Heat Press Area - A live 120 volt AC outlet was missing a cover plate, on or about December 5, 2012.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 323113)
CHICAGO, IL—2026-07-08
SOARDIST USA INC. DBA SOARDIST DISPLAYS AND APPAREL
PENNOCK, MN—2026-07-06
111536 - MINNESOTA SCREEN PRINT - EMBROIDERY INC
PENNOCK, MN—2026-07-06
111528 - MINNESOTA SCREEN PRINT - EMBROIDERY INC
NORWALK, CT—2026-07-06
LAX.COM
NORFOLK, VA—2026-07-01
TEGRA GLOBAL
More inspections in FL
MARIANNA, FL—2026-07-13
PRIMETIME MOBILE MASONRY LLC
MELBOURNE, FL—2026-07-13
OMNIPOTENT BRANDS, LLC
QUINCY, FL—2026-07-13
WALMART
INDIAN ROCKS BEACH, FL—2026-07-10
UNKNOWN CONTRACTOR
CLEARWATER, FL—2026-07-10
ROOFTECH ROOFING & WATERPROOFING INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337691018.