2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: PIERCE METALS

Follow-up inspection · Health discipline

On , OSHA opened a follow-up health inspection of PIERCE METALS in 3820 CHRISTOVAL ROAD, SAN ANGELO, TX 76906 (NAICS 332999). OSHA activity number 337696223.

Watch Pierce Metals — free Get an email when a new federal OSHA severe-injury report for Pierce Metals is published. One employer, no account, unsubscribe in one click.
Establishment
PIERCE METALS
Site address
3820 CHRISTOVAL ROAD
City
SAN ANGELO
State
TX
ZIP
76906
Mailing
1114 SOUTH US HWY 87, SAN ANGELO, TX 76904
Inspection type
Follow-up (F)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332999
Employees
12
Ownership type
A

3 citations on file for this inspection.

1910.243 C01

Serious Gravity 5 6 instances 12 exposed
Issued
Penalty
Initial $4200.00 · Current $2520.00 Reduced
29 CFR 1910.243(c)(1):   Abrasive wheel(s) were used on portable grinder(s) which were not provided with safety guard(s) meeting the requirements specified in 29 CFR 1910.243(c)(1) through (c)(4)(a):  On or about November 30, 2012, approximately six portable angle grinders were used without guarding, exposing employees the hazards of being caught in the spinning wheel or struck by debris of an exploding wheel.  Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that grinders are used with their guarding is in place.
Recent events (2)
  • — I (S) $2520
  • — Z (S) $4200

1910.303 B02

Serious Gravity 1 2 instances 12 exposed
Issued
Abate by
Penalty
Initial $1575.00 · Current $945.00 Reduced
29 CFR 1910.303(b)(2):   Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  On or about November 30, 2012, equipment in the facility was not used in accordance with instructions included in the listing or labeling, exposing employees to a shock hazard.   a: Non-metallic sheathed cable was found powering a receptacle box along the south wall of the facility.  The box was used to power a spotlight.  b: Non-metallic sheathed cable not in conduit was used to power a spotlight along the south wall of the facility.  Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that electrical equipment and wiring is used as listed and labeled.
Recent events (2)
  • — I (S) $945
  • — Z (S) $1575

1910.305 G01 IV A

Serious Gravity 1 1 instance 12 exposed
Issued
Abate by
Penalty
Initial $1575.00 · Current $945.00 Reduced
29 CFR 1910.305(g)(1)(iv)(A):   Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  On or about November 30, 2012, a spotlight in the northeast corner of the facility was powered with an extension cord as permanent wiring, exposing employees to shock and burn hazards.  Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that flexible cords are not used as permanent wiring.
Recent events (2)
  • — I (S) $945
  • — Z (S) $1575

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337696223.