OSHA Inspection: NORTHEASTERN SPECIALTY SYSTEMS

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of NORTHEASTERN SPECIALTY SYSTEMS in LITTLE FALLS HOSPITAL, 140 BURWELL STREET, LITTLE FALLS, NY 13365 (NAICS 238140). OSHA activity number 337814412.

Watch Northeastern Specialty Systems — free Get an email when a new federal OSHA severe-injury report for Northeastern Specialty Systems is published. One employer, no account, unsubscribe in one click.
Site address
LITTLE FALLS HOSPITAL, 140 BURWELL STREET
City
LITTLE FALLS
State
NY
ZIP
13365
Mailing
523 N. PERRY STREET, JOHNSTOWN, NY 12095
Inspection type
Unprogrammed Other (I)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
2
Ownership type
A

2 citations on file for this inspection.

1926.404 B01 II

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $1600.00 · Current $1120.00 Reduced
29 CFR 1926.404(b)(1)(ii):  On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupers for personal protection.    a) First floor, Mechanical Room, on or about 12-12-12:  One employee was operating a sprayer, powered through an extension cord plugged into a duplex receptacle that was not protected by a ground fault circuit interrupter (GFCI).
Recent events (2)
  • — I (S) $1120
  • — Z (S) $1600

1926.416 E01

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.416(e)(1):  Worn or frayed electric cords or cables were used:    a) First floor, Mechanical Room, on or about 12-12-12:  Two employees were operating a drill that exhibited a damaged power cord.