Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: CARTERSVILLE DRYWALL LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CARTERSVILLE DRYWALL LLC in 3693 NORTH COBB PKWY, ACWORTH, GA 30120 (NAICS 238310). OSHA activity number 337837629.

Watch Cartersville Drywall LLC — free Get an email when a new federal OSHA severe-injury report for Cartersville Drywall LLC is published. One employer, no account, unsubscribe in one click.
Site address
3693 NORTH COBB PKWY
City
ACWORTH
State
GA
ZIP
30120
Mailing
14 HOMETOWN CT, CARTERSVILLE, GA 30120
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238310
Employees
2
Ownership type
A

8 citations on file for this inspection.

1926.403 B02

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $1200.00
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification:    a) 3693 North Cobb Pkwy, Acworth, Georgia: Employees using a circular saw were exposed to electrical shock and burns. The electrical box used to supply power to the saw was not approved by a National Recognized Test Laboratory to ensure employees were protected from injuries from faulty or improperly designed equipment.
Recent events (1)
  • — Z (S) $1200

1926.405 B02

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.405(b)(2): All junction boxes were not provided with covers:     a) 3693 North Cobb Pkwy, Acworth, Georgia: Employees using a circular saw were exposed to electrical shock and burns because the electrical box used to supply power to the saw did not have a cover plate installed to protect employees from accidental contact with live parts while plugging in extension cords.
Recent events (1)
  • — Z (S) $0

1926.405 G02 III

Serious Gravity 1 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.405(g)(2)(iii): The repair splice in a hard service flexible cord No. 12 or larger did not retain the insulation, outer sheath properties, and usage characteristics of the cord which was being used:    a) Front of building -The flexible cord of power a circular saw had been spliced in several locations.  These splices were wrapped with electrical tape which did not retain the cord's insulation, and outer sheath properties.    b) Front of building - The flexible extension cord used to power a circular saw had been spliced in several locations.  These splices were wrapped with electrical tape which did not retain the cord's insulation, and outer sheath properties.
Recent events (1)
  • — Z (S) $0

1926.405 G02 IV

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws.    a) 3693 North Cobb Pkwy, Acworth, Georgia: The employer exposed an employee operating a circular saw to electrical shock from an extension cord that did not have strain relief to prevent tension at the joints and terminal screws.
Recent events (1)
  • — Z (S) $0

1926.451 C02 II

Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.451(c)(2)(ii): Unstable objects were used to support platform units:    a) 3693 North Cobb Pkwy, Acworth, Georgia: An employee applying wood sheathing was exposed to a lower level fall hazard of roughly 16-feet while working from a scaffold platform that was bearing on the rails of two aerial lifting devices.
Recent events (1)
  • — Z (S) $2800

1926.451 G01 VII

Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.    a) 3693 North Cobb Pkwy, Acworth, Georgia: An employee applying wood sheathing was exposed to a lower level fall hazard of roughly 16-feet while working from a single platform scaffold. There was no fall protection in use or on site.
Recent events (1)
  • — Z (S) $0

1926.501 B01

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.    a) 3693 North Cobb Pkwy, Acworth, Georgia: An employee installing wood sheathing was exposed to a lower level fall hazard of roughly 14-feet while standing on a steel cross beam. The working surface was unguarded and there was no means of fall protection in use.
Recent events (1)
  • — Z (S) $0

1926.453 B02 V

Serious Gravity 5 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $2000.00
29 CFR 1926.453(b)(2)(v):  A body belt with lanyard attached to the boom or basket was not worn by employees working from aerial lifts:    a) Front of building - An employee was exposed to a lower level fall hazard of approximately 14-feet while working from an articulating/extensible boom lift without approved fall protection equipment.     b) Front of building - An employee was exposed to a lower level fall hazard of approximately 14-feet while working from an articulating boom lift without approved fall protection equipment.
Recent events (1)
  • — Z (S) $2000

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337837629.