Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: BLACKDOG BUILDERS

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of BLACKDOG BUILDERS in 18 RESERVATION ROAD, ANDOVER, MA 01810 (NAICS 236118). OSHA activity number 337966014.

Watch Blackdog Builders — free Get an email when a new federal OSHA severe-injury report for Blackdog Builders is published. One employer, no account, unsubscribe in one click.
Establishment
BLACKDOG BUILDERS
Site address
18 RESERVATION ROAD
City
ANDOVER
State
MA
ZIP
01810
Mailing
7 RED ROOF LANE UNIT 1, SALEM, NH 03079
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236118
Employees
3
Ownership type
A

3 citations on file for this inspection.

1926.403 B01 I

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $1360.00 · Current $850.00 Reduced
29 CFR 1926.403(b)(1)(i):     Suitability for installation and use in conformity with the provisions of this subpart. Suitability of equipment for an identified purpose may be evidenced by listing, labeling, or certification for that identified purpose.    (a) Location - 18 Reservation Road, Andover, MA:    On or about 12/19/12, the employer allowed the use of a relocatable power tap on the job site, contrary to the equipments' listing.
Recent events (2)
  • — I (S) $850
  • — Z (S) $1360

1926.405 G02 III

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $0.00 Reduced
29 CFR 1926.405(g)(2)(iii):     Splices. Flexible cords shall be used only in continuous lengths without splice or tap. Hard service flexible cords No. 12 or larger may be repaired if spliced so that the splice retains the insulation, outer sheath properties, and usage characteristics of the cord being spliced.    (a) Location - 18 Reservation Road, Andover, MA:    On or about 12/19/12, an improperly spliced flexible cord was used to power a Mikita circular saw.
Recent events (2)
  • — I (S) $0
  • — Z (S) $1600

1926.501 B13

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1200.00 Reduced
29 CFR 1926.501(b)(13):     "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502.    (a) Location - 18 Reservation Road, Andover, MA:    On or about 12/19/12, the employer failed to ensure that a worker was provided with and utilized fall protection while working on an 11-foot porch roof.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000