Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: WATTON ENTERPRISES

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of WATTON ENTERPRISES in 420 WELLS STREET, CHIPPEWA FALLS, WI 54729 (NAICS 331524). OSHA activity number 338025216.

Watch Watton Enterprises — free Get an email when a new federal OSHA severe-injury report for Watton Enterprises is published. One employer, no account, unsubscribe in one click.
Establishment
WATTON ENTERPRISES
Site address
420 WELLS STREET
City
CHIPPEWA FALLS
State
WI
ZIP
54729
Mailing
420 WELLS STREET, CHIPPEWA FALLS, WI 54729
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331524
Employees
9
Ownership type
A

4 citations on file for this inspection.

1910.212 A03 II

Serious Gravity 5 2 instances 1 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $1120.00 Reduced
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):     (a) Machining Area; Two Monarch Machine Tool Co. Lathes (4109-CC732 and 26239) were operated without guarding the rotating chuck.
Recent events (2)
  • — I (S) $1120
  • — Z (S) $1600

1910.147 D02

Serious Gravity 5 6 instances 2 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $1120.00 Reduced
29 CFR 1910.147(d)(2): The machine or equipment was not turned off or shut down using the procedures established for the machine or equipment:     (a) Machining Area; Machinery such as, but not limited to, the Mazak CNC vertical and horizontal machining center(s), the Mazak CNC Slant Turn 25 ATC M/C, and the Super Quick Turn (s/n 107948) were not shut down when servicing equipment.
Recent events (2)
  • — I (S) $1120
  • — Z (S) $1600

1910.147 D03

Serious Gravity 5 6 instances 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s):   (a)  Machining Area; Machinery such as, but not limited to, the Mazak CNC vertical and horizontal machining centers, the Mazak CNC Slant Turn 25 ATC M/C, and the Super Quick Turn (s/n 107948) were not isolated from energy source(s) when servicing equipment.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 D04 I

Serious Gravity 5 6 instances 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees:   (a)  Machining Area; Machinery such as, but not limited to, the Mazak CNC vertical and horizontal machining centers, the Mazak CNC Slant Turn 25 ATC M/C, and the Super Quick Turn (s/n 107948) did not have lockout or tagout devices affixed to isolating energy device(s) by authorized employee(s).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338025216.