OSHA Inspection: FOLDING GUARD CORPORATION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of FOLDING GUARD CORPORATION in 5858 W. 73RD. STREET, BEDFORD PARK, IL 60638 (NAICS 326199). OSHA activity number 338050222.

Watch Folding Guard Corporation — free Get an email when a new federal OSHA severe-injury report for Folding Guard Corporation is published. One employer, no account, unsubscribe in one click.
Site address
5858 W. 73RD. STREET
City
BEDFORD PARK
State
IL
ZIP
60638
Mailing
5858 W. 73RD. STREET, BEDFORD PARK, IL 60638
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
104
Ownership type
A

9 citations on file for this inspection.

5(a)(1)

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $6930.00 · Current $0.00 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees    North West B5 - On or about December 27, 2012, provisions were not made to prevent unintended operation (actuation)of the foot treadle of the Diacro, model #18-48, serial #JB-1013 press brake due to falling or moving objects or by accidentally stepping on the treadle.
Recent events (2)
  • — I (O) $0
  • — Z (S) $6930

1910.147 C04 I

Serious Gravity 5 20 instances 62 exposed
Issued
Abate by
Penalty
Initial $5940.00 · Current $2970.00 Reduced
29 CFR 1910.147(c)(4)(i): Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section:    Throughout facility - On or about December 27, 2012, procedures were not developed, documented and utilized for the control of potentially hazardous energy, thereby exposig employees to the unexpected re-energization of machinery.
Recent events (2)
  • — I (S) $2970
  • — Z (S) $5940

1910.147 C06 I

Serious Gravity 5 3 instances 62 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(6)(i): The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.    Throughout facility - On or about December 27, 2012, the employer did not conduct periodic inspections of the energy control procedures at least annually to ensure the procedures were being followed, thereby exposing employees to unexpected energization of machinery.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A03 II

Serious Gravity 10 7 instances 43 exposed
Issued
Abate by
Penalty
Initial $6930.00 · Current $3465.00 Reduced
29 CFR 1910.212(a)(3)(ii):     The point of operation of machines whose operation exposes an employee to injury, shall be guarded. The guarding device shall be in conformity with any appropriate standards therefor, or, in the absence of applicable specific standards, shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle.    e. Throughout facility - On or about December 27, 2012, the unused portion of the blade of the vertical DoAll bandsaw, model # ML, serial # 4610333, were not enclosed or guarded, thereby exposing employees to the hazards associated with reciprocating blades.      f. Throughout facility - On or about December 27, 2012, the unused portion of the blade of the horizontal Wells bandsaw, model #58B serial #9157, were not enclosed or guarded, thereby exposing employees to the hazards associated with reciprocating blades.
Recent events (2)
  • — I (S) $3465
  • — Z (S) $6930

1910.219 D01

Deleted Serious Gravity 1 1 instance 4 exposed
Issued
Penalty
Initial $2970.00 · Current $0.00 Reduced
29 CFR 1910.219(d)(1): Guarding. Pulleys, any parts of which are seven (7) feet or less from the floor or working platform, shall be guarded in accordance with the standards specified in paragraphs (m) and (o) of this section.     Maintenance Shop - On or about December 27, 2012, the pulleys on the KBC Machinery belt sander #20, model # 690, serial # 0897275 was not guarded completely, thereby exposing employees to the hazards associated with moving parts.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2970

1910.219 E01 I

Deleted Serious Gravity 1 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.219(e)(1)(i): Where both runs of horizontal belts are seven (7) feet or less from the floor level, the guard shall extend to at least fifteen (15) inches above the belt or to a standard height, except that where both runs of a horizontal belt are 42 inches or less from the floor, the belt shall be fully enclosed in accordance with paragraphs (m) and (o) of this section.    Maintenance Shop - On or about December 27, 2012, the horizontal belts on the KBC belt sander #20, model # 690, serial # 0897275 were not guarded completely, thereby exposing employees to the hazards associated with moving parts.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 B02

Other-than-serious 1 instance 60 exposed
Issued
Abate by
Penalty
Initial $5049.00 · Current $0.00 Reduced
29 CFR 1910.303(b)(2): Installation and use. Listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling.    Maintenance Department - On or about December 27, 2012, the employer failed to use electrical equipment extension cords in accordance with its listing or labeling, thereby exposing employees to electrical hazards.
Recent events (2)
  • — I (O) $0
  • — Z (S) $5049

1910.303 B07 I

Other-than-serious 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings shall be effectively closed to afford protection substantially equivalent to the wall of the equipment.    Production Area - On or about December 27, 2012, the employer failed to cover knockouts on boxes thereby, exposing employees to electrical hazards.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.303 C03 I

Other-than-serious 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(c)(3)(i): Conductors shall be spliced or joined with splicing devices identified for the use or by brazing, welding, or soldering with a fusible metal or alloy. Soldered splices shall first be spliced or joined to be mechanically and electrically secure without solder and then soldered. All splices and joints and the free ends of conductors shall be covered with an insulation equivalent to that of the conductors or with an insulating device identified for the purpose.    Maintenance Department - On or about December 27, 2012, the employer failed to insulate conductors with an insulating device identified for that purpose on the Miller Welder model number CP-300, serial number JG060089, thereby exposing employees to electrical hazards.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

View FOLDING GUARD CORPORATION's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338050222.