SAINT LOUIS, MO —
OSHA Inspection: ST. LOUIS LITHOGRAPHING COMPANY
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ST. LOUIS LITHOGRAPHING COMPANY in 6880 HEEGE ROAD, SAINT LOUIS, MO 63123 (NAICS 323110). OSHA activity number 338130222.
Where did this inspection happen?
- Establishment
- ST. LOUIS LITHOGRAPHING COMPANY
- Site address
- 6880 HEEGE ROAD
- City
- SAINT LOUIS
- State
- MO
- ZIP
- 63123
- Mailing
- 6880 HEEGE ROAD, SAINT LOUIS, MO 63123
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 323110
- Employees
- 110
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.212 A03 II
- Issued
- Abate by
- Penalty
- Initial $4500.00 · Current $2250.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): (a) Located at 2 color press employees were not protected from crushing hazards where the loading elevator terminated at floor level. Guarding was not provided to prevent employees from entering there body or limbs into the space below the elevator when elevated while the elevator was operational. (b) Located at the die cutter model CO1PM03 employees were exposed to points of operation at the top, sides, and front where could easily place there hands. Abatement certification and abatement document is required for this violation. The documentation should include written verification of abatement, applicable measurement or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
- — I (S) $2250
- — Z (S) $4500
1910.219 F03
- Issued
- Abate by
- Penalty
- Initial $4500.00 · Current $2250.00 Reduced
General-duty citation text
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven feet or less above floors or platforms were not enclosed: (a) Located in the work site the chain and sprocket driving the load turner were not enclosed allowing the potential for employees to insert their hands into the point of operation. Abatement verification is required for this violation. The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
- — I (S) $2250
- — Z (S) $4500
1910.242 B
- Issued
- Abate by
- Penalty
- Initial $4500.00 · Current $2250.00 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i. (a)At the Bobst area air pressure to a blow gun being used for cleaning purposes , when tested, was 80psi plus. Abatement verification is required for this violation. The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
- — I (S) $2250
- — Z (S) $4500
1910.303 B02
- Issued
- Abate by
- Penalty
- Initial $4500.00 · Current $2250.00 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: (a)In the ink room a quad junction box was mounted to the front of the ink agitator and was wired via cord and plug to switches controlling the operation of the device. Abatement certification and abatement document is required for this violation. The documentation should include written verification of abatement, applicable measurement or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
- — I (S) $2250
- — Z (S) $4500
1910.304 B04 II B
- Issued
- Abate by
- Penalty
- Initial $4500.00 · Current $2250.00 Reduced
General-duty citation text
29 CFR 1910.304(b)(4)(ii)(B): A receptacle connected to a branch circuit supplying two or more receptacles was supplying a total cord and plug connected load in excess of the maximum specified in Table s-4. (a) At the work site a Woods relocatable power tap rated at 12 amps of load and connected to a Lakewood heater rated at 1500 watts(13.5) amps was connected to a receptacle rated for a maximum load of 12 amps. Corrected during inspection
Recent events (2)
- — I (S) $2250
- — Z (S) $4500
More inspections in this industry (NAICS 323110)
MINNEAPOLIS, MN—2026-05-20
111284 - MARTH GROUP LLC DBA ENPOINTE
GLENDALE, KY—2026-02-04
68801 - PG-GERALD LLC
PORTLAND, OR—2026-01-16
317742947 - PEP PRINTING INC
MINNEAPOLIS, MN—2025-11-18
110299 - OMEGA LITHOGRAPH INC
BELLINGHAM, WA—2025-09-05
WA317987718 - CAPITOL CITY PRESS INC
More inspections in MO
CLINTON, MO—2026-07-14