BRIDGEPORT, CT —
OSHA Inspection: SRG SIDING, ROOFING & GUTTERS, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SRG SIDING, ROOFING & GUTTERS, LLC in 31-33 STOEHR PLACE, BRIDGEPORT, CT 06606 (NAICS 238160). OSHA activity number 338143225.
Where did this inspection happen?
- Establishment
- SRG SIDING, ROOFING & GUTTERS, LLC
- Site address
- 31-33 STOEHR PLACE
- City
- BRIDGEPORT
- State
- CT
- ZIP
- 06606
- Mailing
- 98 PORTER STREET APT #1, BRIDGEPORT, CT 06606
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 4
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.102 A01
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $2000.00
General-duty citation text
29 CFR 1926.102(a)(1): Employees shall be provided with eye and face protection equipment when machines or operations present potential eye or face injury from physical, chemical, or radiation agents. WORKSITE: The employee, installing roof sheathing, using a pneumatic nailing device was not wearing eye protection.
Recent events (1)
- — Z (S) $2000
1926.501 B13
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $2800.00
General-duty citation text
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. WORKSITE: The employees installing roof shingles on an 11/ 12 pitch roof were not protected from the hazard of falling 21 feet, 6 inches to the ground by the use of appropriate fall protection systems/devices.
Recent events (1)
- — Z (S) $2800
1926.1053 B01
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $2000.00
General-duty citation text
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support. WORKSITE: The side rails of the Werner model 1540-2 40 foot aluminum extension ladder, used by employees to access the roof did not extend at least 3 feet above the roof and no hand hold or equivalent was provided.
Recent events (1)
- — Z (S) $2000
1926.1053 B21
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $2800.00
General-duty citation text
29 CFR 1926.1053(b)(21): Each employee shall use at least one hand to grasp the ladder when progressing up and/or down the ladder. WORKSITE: The employees engaged in residential roofing activities were manually carrying partial and full sheets of plywood up the ladder and were unable to maintain at least three points of contact at all times with the ladder.
Recent events (1)
- — Z (S) $2800
1926.1053 B22
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1053(b)(22): An employee shall not carry any object or load that could cause the employee to lose balance and fall. WORKSITE: The employees engaged in residential roofing activities were manually carrying partial and full sheets of plywood onto the roof using the ladder.
Recent events (1)
- — Z (S) $0
More inspections at SRG SIDING, ROOFING & GUTTERS, LLC
WATERBURY, CT—2012-09-26 00:00:00
SRG SIDING, ROOFING & GUTTERS, LLC
View SRG SIDING, ROOFING & GUTTERS, LLC's full OSHA safety record →
More inspections in this industry (NAICS 238160)
FAIRVIEW, TN—2026-07-16
MARVIN PINERA
CARSON CITY, NV—2026-07-16
UNKNOWN/INVALID ESTABLISHMENT
BANNOCKBURN, IL—2026-07-16
ROOFING H.P. LLC
LOXLEY, AL—2026-07-16
CARLOS CHE
BALTIMORE, MD—2026-07-16
VAL CONSTRUCTION INC
More inspections in CT
ENFIELD, CT—2026-07-16
MOMS ENFIELD
DAYVILLE, CT—2026-07-16
HARBOR FREIGHT
NEW BRITAIN, CT—2026-07-14
JANANII, LLC
NEWINGTON, CT—2026-07-14
TRUSS MANUFACTURING INC
NORTH BRANFORD, CT—2026-07-14
NYK STATEWIDE MOLINA CONSTRUCTION LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338143225.