OSHA Inspection: PERFORMANCE ELASTOMERS INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of PERFORMANCE ELASTOMERS INC. in 7162 STATE ROUTE 88, RAVENNA, OH 44266 (NAICS 326220). OSHA activity number 338166614.

Watch Performance Elastomers INC. — free Get an email when a new federal OSHA severe-injury report for Performance Elastomers INC. is published. One employer, no account, unsubscribe in one click.
Site address
7162 STATE ROUTE 88
City
RAVENNA
State
OH
ZIP
44266
Mailing
7162 STATE ROUTE 88, RAVENNA, OH 44266
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326220
Employees
85
Ownership type
A

9 citations on file for this inspection.

1910.22 A01

Serious Gravity 5 1 instance 15 exposed
Issued
Penalty
Initial $2800.00 · Current $1400.00 Reduced
29 CFR 1910.22(a)(1):  All places of employment, passageways, storerooms, and service rooms were not kept clean and orderly and in a sanitary condition:    On or about January 9, 2013, near the taping area, adjacent to the emergency exit along the north wall, numerous drop cords, equipment, pallets, and other debris were observed presenting a slipping/tripping hazard.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1910.37 A03

Serious Gravity 5 1 instance 15 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.37(a)(3):  Exit route was not free and unobstructed:    On or about January 9, 2013, the route to the emergency exit in the taping department, north wall, was impeded by a drop cord that ran across the exit route which could result in a slip/trip hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.37 A04

Serious Gravity 5 1 instance 15 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.37(a)(4):  Safeguards designed to protect  employees during an emergency (e.g. sprinkler systems, alarm systems, fire doors, exit lighting) were not in proper working order at all times:    On or about January 9, 2013, the exit sign over the emergency exit doorway in the taping department, north wall, was in disrepair as it had no marking present over the light fixture.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.106 D05 I

Serious Gravity 5 1 instance 15 exposed
Issued
Penalty
Initial $2800.00 · Current $1400.00 Reduced
29 CFR 1910.106(d)(5)(i):  Flammable liquids, including stock for sale, were not stored so as to limit use of exits, stairways, or areas normally used for the safe egress of people:    On or about January 9, 2013, two barrels of flammable liquids were located directly adjacent to the emergency exit in the taping department, north wall.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1910.212 A01

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1400.00 Reduced
29 CFR 1910.212(a)(1):  One or more methods of machine guarding were not provided to protect the operator and other employees in the machine area from hazards such as those created by ingoing nip points:    On or about January 9, 2013, the powered conveyor(s) (Straub Design Co. puller machine #234-02) on the #4 HATS line, taping department, had several open points that pull the rubber material through the application line, exposing workers to ingoing nip points.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1910.219 C02 I

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1400.00 Reduced
29 CFR 1910.219(c)(2)(i):  All exposed parts of horizontal shafting seven (7) feet or less from floor or working platform, excepting runways used exclusively for oiling, or running adjustments, were not protected by a stationary casing enclosing shafting completely:    On or about January 9, 2013,  the drive shaft for the take away conveyor on the #4 HATS line, taping department,  had no guard present.  The shaft was approximately three (3) feet from floor level.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1910.303 B02

Serious Gravity 5 1 instance 15 exposed
Issued
Penalty
Initial $3500.00 · Current $1750.00 Reduced
29 CFR 1910.303(b)(2):  Listed or labeled equipment was not installed and used in accordance with any instructions included in the listing or labeling:    On or about January 9, 2013, the surge protector in use in the taping area, next to the HATS line, had an unknown interrupting rating for the equipment plugged into the protector.
Recent events (2)
  • — I (S) $1750
  • — Z (S) $3500

1910.305 G02 III

Serious Gravity 5 1 instance 15 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(2)(iii):   Flexible cords and cables were not connected to devices and fittings so that the strain relief is provided that will prevent pull from being directly transmitted to joints or terminal screws:    On or about January 9, 2013,  the flexible power cord to the fan near the taping area was not connected by a strain relief as required.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 F06 I

Other-than-serious 1 instance 5 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(f)(6)(i):  The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the information required by 29 CFR 1910.1200(f)(1)(i) through 29 CFR 1910.1200(f)(1)(v):    On or about January 9, 2013, the employer had not properly labeled the container of heptane in use on the #4 HATS taping line, closest to the back wall, as to the hazardous contents within.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0