MIDDLE POINT, OH —
OSHA Inspection: HOPSCO ENERGY PRODUCTS, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of HOPSCO ENERGY PRODUCTS, LLC in 111 SOUTH MAIN ST., MIDDLE POINT, OH 45863 (NAICS 333415). OSHA activity number 338197817.
Where did this inspection happen?
- Establishment
- HOPSCO ENERGY PRODUCTS, LLC
- Site address
- 111 SOUTH MAIN ST.
- City
- MIDDLE POINT
- State
- OH
- ZIP
- 45863
- Mailing
- P.O. BOX 281, MIDDLE POINT, OH 45863
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333415
- Employees
- 5
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.178 L01 I
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator was competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l). Hopsco Energy Products, LLC, located at 111 South Main St., Middle Point, OH 45863: On or about January 10, 2013, the employer did not ensure that employees, operating powered industrial vehicle Hyster (Model S30E, S/N D002D03778X), are competent to complete the task, exposing employees to struck-by, caught in between, and tip over hazards. The employer did not ensure that each forklift operator received formal instructions and practical training on how to operate a powered industrial vehicle, as well as operators performance was not evaluated. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1910.178 L04 III
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years: Hopsco Energy Products, LLC, located at 111 South Main St., Middle Point, OH 45863: On or about January 10, 2013, the employer did not ensure that performance of the employee, operating powered industrial vehicle Hyster (Model S30E, S/N D002D03778X), was evaluated at least once every three years, exposing employees to struck-by, caught-in-between, and tip-over hazards. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.178 P01
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s): Hopsco Energy Products, LLC, located at 111 South Main St., Middle Point, OH 45863: On or about January 10, 2013, the employer did not remove powered industrial vehicle Hyster (Model S30E, S/N D002D03778X) from use based on mechanical defect such as, but not limited to, hydraulic oil leak. Employees were exposed to struck-by and caught-in-between hazards. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1910.178 Q07
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.178(q)(7): Industrial trucks were not examined before being placed in service, and shall not be placed in service if the examination shows any condition adversely affecting the safety of the vehicle. Such examination shall be made at least daily: Hopsco Energy Products, LLC, located at 111 South Main St., Middle Point, OH 45863: On or about January 10, 2013, the employer did not ensure that daily examinations of the powered industrial vehicle Hyster (Model S30E, S/N D002D03778X) were conducted before being put into service. Employees were exposed to struck-by and caught-in-between hazards. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A01
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $800.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices,electronic safety devices, etc. Hopsco Energy Products, LLC, located at 111 South Main St., Middle Point, OH 45863: On or about January 10, 2013, the employer failed to ensure that King drill press (Model 4120-0, Serial # is not identified), located in the facility's operations area, was properly guarded in order to prevent employees from inadvertently being caught by the rotating chuck during operation. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
- — I (S) $800
- — Z (S) $1600
1910.252 B02 III
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $800.00 Reduced
General-duty citation text
29 CFR 1910.252(b)(2)(iii): Workers and other persons adjacent to the welding area were not protected from the rays by noncombustible or flameproof screens or shields: Hopsco Energy Products, LLC, located at 111 South Main St., Middle Point, OH 45863: On or about January 10, 2013, the employer did not ensure that the welding area in the facility was enclosed with noncombustible or flameproof screens or shields, exposing employees, adjacent to the welding area, to eye injuries from the welding rays. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
- — I (S) $800
- — Z (S) $1600
More inspections in this industry (NAICS 333415)
LAUREL, MS—2026-07-01
THERMO-KOOL
OSSEO, WI—2026-07-01
TITAN AIR, LLLP
OSSEO, WI—2026-06-22
TITAN AIR, LLLP
LA CROSSE, WI—2026-05-28
TRANE U.S. INC.
COLONIAL HEIGHTS, VA—2026-05-26
HILL PHOENIX, INC.
More inspections in OH
WELLINGTON, OH—2026-07-16
WHIRLAWAY CORPORATION
WAUSEON, OH—2026-07-16
WATSON WELL DRILLING INC.
SEVEN HILLS, OH—2026-07-15
STONEY ACRES BUILDERS LLC
SEVEN HILLS, OH—2026-07-15
GRB ENTERPRISES LLC
CHILLICOTHE, OH—2026-07-15
KENWORTH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338197817.