OSHA Inspection: FOUR ANGLE HOME IMPROVEMENT

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of FOUR ANGLE HOME IMPROVEMENT in 2697 COVERED BRIDGE RD., MERRICK, NY 11566 (NAICS 236118). OSHA activity number 338215213.

Watch Four Angle Home Improvement — free Get an email when a new federal OSHA severe-injury report for Four Angle Home Improvement is published. One employer, no account, unsubscribe in one click.
Site address
2697 COVERED BRIDGE RD.
City
MERRICK
State
NY
ZIP
11566
Mailing
332 LEXINGTON AVE., WEST BABYLON, NY 11704
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236118
Employees
6
Ownership type
A

3 citations on file for this inspection.

1926.501 B13

Serious Gravity 5 1 instance 4 exposed
Issued
Penalty
Initial $2000.00 · Current $2000.00
29 CFR 1926.501(b)(13):  Employees engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employees provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):    a)Worksite, 2697 Covered Bridge Rd.,Merrick- employees were installing a roof with a pitch of approximately 8-12 and  working at a height of approximately 18 feet without fall protection; on or about 01/09/13.     Note:  The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (1)
  • — Z (S) $2000

1926.416 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $1600.00 · Current $1600.00
29 CFR 1926.416(a)(1): Employees were permitted to work in proximity to electric power circuits and were not protected against electric shock by de-energizing and grounding the circuits or effectively guarding the circuits by insulation or other means:    a) Worksite, 2697 Covered Bridge Rd., Merrick- employee was exposed to electric shock while working within several inches of an unprotected and energized 220v powerline leading to home from street electric pole. on or about 01/09/13.      Note:  The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (1)
  • — Z (S) $1600

1926.1053 B12

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $1600.00 · Current $1600.00
29 CFR 1926.1053(b)(12): Ladders used where the employee or the ladder could contact exposed energized electrical equipment did not have nonconductive siderails:    a) Worksite, 2697 Covered Bridge Rd., Merrick- employee was working on a 32' aluminum extension ladder less than 12 inches from an energized 220v powerline. The aluminum ladder did not have non conductive siderails; on or about 01/09/13.    Note:  The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (1)
  • — Z (S) $1600

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338215213.