MERRICK, NY —
OSHA Inspection: FOUR ANGLE HOME IMPROVEMENT
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of FOUR ANGLE HOME IMPROVEMENT in 2697 COVERED BRIDGE RD., MERRICK, NY 11566 (NAICS 236118). OSHA activity number 338215213.
Where did this inspection happen?
- Establishment
- FOUR ANGLE HOME IMPROVEMENT
- Site address
- 2697 COVERED BRIDGE RD.
- City
- MERRICK
- State
- NY
- ZIP
- 11566
- Mailing
- 332 LEXINGTON AVE., WEST BABYLON, NY 11704
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236118
- Employees
- 6
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.501 B13
- Issued
- Penalty
- Initial $2000.00 · Current $2000.00
General-duty citation text
29 CFR 1926.501(b)(13): Employees engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employees provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a)Worksite, 2697 Covered Bridge Rd.,Merrick- employees were installing a roof with a pitch of approximately 8-12 and working at a height of approximately 18 feet without fall protection; on or about 01/09/13. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (1)
- — Z (S) $2000
1926.416 A01
- Issued
- Penalty
- Initial $1600.00 · Current $1600.00
General-duty citation text
29 CFR 1926.416(a)(1): Employees were permitted to work in proximity to electric power circuits and were not protected against electric shock by de-energizing and grounding the circuits or effectively guarding the circuits by insulation or other means: a) Worksite, 2697 Covered Bridge Rd., Merrick- employee was exposed to electric shock while working within several inches of an unprotected and energized 220v powerline leading to home from street electric pole. on or about 01/09/13. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (1)
- — Z (S) $1600
1926.1053 B12
- Issued
- Penalty
- Initial $1600.00 · Current $1600.00
General-duty citation text
29 CFR 1926.1053(b)(12): Ladders used where the employee or the ladder could contact exposed energized electrical equipment did not have nonconductive siderails: a) Worksite, 2697 Covered Bridge Rd., Merrick- employee was working on a 32' aluminum extension ladder less than 12 inches from an energized 220v powerline. The aluminum ladder did not have non conductive siderails; on or about 01/09/13. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (1)
- — Z (S) $1600
More inspections in this industry (NAICS 236118)
CORTLANDT MANOR, NY—2026-07-13
RJW RENOVATIONS, LLC
VANCOUVER, WA—2026-07-08
WA317991978 - DLS CONTRACTING INC
NEWPORT BEACH, CA—2026-07-08
DRAKE SMITH CONSTRUCTION
BRIDGEVILLE, PA—2026-07-08
EXTREME DECKS
COLUMBUS, OH—2026-07-07
QUALITY BUILDS OHIO LLC
More inspections in NY
POUGHKEEPSIE, NY—2026-07-13
MARCO BOARD HOUSE, INC.
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CORTLANDT MANOR, NY—2026-07-13
RJW RENOVATIONS, LLC
HEMPSTEAD, NY—2026-07-13
NYSDOCCS NASSAU AREA OFFICE
NIAGARA FALLS, NY—2026-07-10
NTVI FEDERAL INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338215213.