WESTBOROUGH, MA —
OSHA Inspection: SHANE BUILDERS
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SHANE BUILDERS in 183 TURNPIKE RD TO BE XTRA MART GAS STATION, WESTBOROUGH, MA 01581 (NAICS 238130). OSHA activity number 338243017.
Where did this inspection happen?
- Establishment
- SHANE BUILDERS
- Site address
- 183 TURNPIKE RD TO BE XTRA MART GAS STATION
- City
- WESTBOROUGH
- State
- MA
- ZIP
- 01581
- Mailing
- 633 WEST SHERMAN ST, CARO, MI 48723
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 3
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B11
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $2800.00
General-duty citation text
29 CFR 1926.501(b)(11):Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: (a) 183 Turnpike Rd Westborough, MA: On or about January 14, 2013, three employees were observed working on this steep roof more than 15 feet above the ground below without any fall protection as required by this subpart: Specific abatement documentation that this violation has been corrected must be provided within 10 days of the abatement in accordance with 29 CFR 1903.19(d)(1).
Recent events (1)
- — Z (S) $2800
1926.1053 B01
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $2800.00
General-duty citation text
29 CFR 1926.1053(b)(1):When portable ladders are used for access to an upper landing surface, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access: (a) 183 Turnpike Rd Westborough, MA : On or about January 14, 2013, employees were using 2 seperate extension ladders to access the roof, neither of which extended any distance past the roof surface as required by this subpart: Specific abatement documentation that this violation has been corrected must be provided within 10 days of the abatement in accordance with 29 CFR 1903.19(d)(1).
Recent events (1)
- — Z (S) $2800
More inspections in this industry (NAICS 238130)
ENCINITAS, CA—2026-07-13
LOU RIDDLE CONSTRUCTION
MERIDIAN, ID—2026-07-10
IDAHO HOMES CONSTRUCTION LLC
KIMBERLY, WI—2026-07-10
ENRIQUE RESENDIC
METTER, GA—2026-07-10
M.A.P.C CONSTRUCTION, LLC
SLINGER, WI—2026-07-10
RAMIREZ HOME BUILDERS LLC
More inspections in MA
WORCESTER, MA—2026-07-10
QUINSIGAMOND COMMUNITY COLLEGE
FITCHBURG, MA—2026-07-10
KELLEY WOOD PRODUCTS, INC.
EVERETT, MA—2026-07-10
HORIZON RETAIL CONSTRUCTION INC
NORTON, MA—2026-07-09
DYNAMIC RESIDENTIAL ROOF MARKETING, LLC
NORTON, MA—2026-07-09
LM GENERAL CONSTRUCTION INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338243017.