OSHA Inspection: NORWALK POWERED METALS INCORPORATED

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of NORWALK POWERED METALS INCORPORATED in 1100 BOSTON AVENUE, BUILDING #3, BRIDGEPORT, CT 06610 (NAICS 332117). OSHA activity number 338283617.

Watch Norwalk Powered Metals Incorporated — free Get an email when a new federal OSHA severe-injury report for Norwalk Powered Metals Incorporated is published. One employer, no account, unsubscribe in one click.
Site address
1100 BOSTON AVENUE, BUILDING #3
City
BRIDGEPORT
State
CT
ZIP
06610
Mailing
1100 BOSTON AVENUE, BUILDING #3, BRIDGEPORT, CT 06610
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332117
Employees
25
Ownership type
A

4 citations on file for this inspection.

1910.217 B07 V A

Serious Gravity 5 2 instances 1 exposed
Issued
Penalty
Initial $1360.00 · Current $952.00 Reduced
29 CFR 1910.217(b)(7)(v)(a): Each two-hand control for single stroke operations on mechanical power press(es) using part revolution clutches was not protected against unintended operation.      Location: Press Area, 110 Boston Avenue, Building #3, Bridgeport, CT 06610      The 1 1/2 inch diameter two hand controls 56 1/2 inches on center above the floor on the Stokes Pennwalt 20 ton partial revolution mechanical power press, press #18, were not equipped with devices to protect the controls against unintended operation.
Recent events (2)
  • — I (S) $952
  • — Z (S) $1360

1910.217 B07 V B

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.217(b)(7)(v)(b): The two hand control system for mechanical power press(es) was not designed to permit an adjustment requiring concurrent pressure from both hands during the die closing portion of the stroke.    Location: Press Area, 1100 Boston Avenue, Building #3, Bridgeport, CT 06610    The two hand controls on the #18 Stokes Pennwalt 20 ton partial revolution mechanical power press were not concurrent thereby requring concurrent pressure from both hands during the die closing portion of the stroke.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.217 B07 V C

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.217(b)(7)(v)(c): The two hand control system of mechanical power press(es) using part revolution clutches did not incorporate an antirepeat feature.    Location: Press Area, 1100 Boston Avenue, Building #3, Bridgeport, CT 06610    The two hand controls on the #18 Stokes Pennwalt 20 ton partial revolution mechanical power press were not equipped with an anti-repeat feature.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.217 C02 I B

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $1360.00 · Current $952.00 Reduced
29 CFR 1910.217(c)(2)(i)(b): Point of operation guard(s) on mechanical power press(es) did not conform to the maximum permissible opening(s) specified in Table O-10.    Location: Press Area, 1100 Boston Avenue, Building #3, Bridgeport, CT 06610    The 4 inch wide, 5 inch long opening within the point of operation barrier guard 9 inches from the point of operation on the Gasbarre Products 60 ton partial revolution mechanical power press did not conform to the O-10 table in that the maximum barrier guard opening allowed is 1 1/4 inches.