HOUSTON, TX —
OSHA Inspection: THERMO-MOLD
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of THERMO-MOLD in 5801 BERRYBROOK, HOUSTON, TX 77017 (NAICS 326122). OSHA activity number 338287410.
Where did this inspection happen?
- Establishment
- THERMO-MOLD
- Site address
- 5801 BERRYBROOK
- City
- HOUSTON
- State
- TX
- ZIP
- 77017
- Mailing
- 5801 BERRYBROOK, HOUSTON, TX 77017
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326122
- Employees
- 12
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.23 A01
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $1540.00 Reduced
General-duty citation text
29 CFR 1910.23(a)(1): Every stairway floor opening was not guarded by a standard railing constructed in accordance with paragraph (e) of this section on all exposed sides (except at the entrance to the stairway): a) At the facility, on or about January 15, 2013 - Employees were exposed to fall hazards of 9 feet when approaching the top of stairs used to access a storage area for product.
Recent events (2)
- — I (S) $1540
- — Z (S) $2800
1910.23 C01
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards: a) At the facility, on or about January 15, 2013 - Employees were exposed to fall hazards of approximately 9 feet when accessing an area used to store materials and work products.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.219 E03 I
- Issued
- Penalty
- Initial $2800.00 · Current $1540.00 Reduced
General-duty citation text
29 CFR 1910.219(e)(3)(i): Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o): (a) At the facility, on or about January 15, 2013 - An employee was exposed to caught-in hazards from an exposed inclined belt on a DAYTON Drive Motor (MN 6K784A) at an approximate speed of 1725 rpms while operating a furnace used to heat and seal product.
Recent events (2)
- — I (S) $1540
- — Z (S) $2800
1910.305 B01 II
- Issued
- Penalty
- Initial $2000.00 · Current $1100.00 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: a) On the north wall behind the Milltronics CNC Machine (serial number 6594, model number VM24E), on or about January 15, 2013 - Employees were exposed to electrical hazards when working in their work stations around the Square D junction box(240 volts) with missing knock-outs. b) On the north wall behind the 5'x8' ZMD International, Inc. Thermomolder (serial number 1578, model number HT400), on or about January 15, 2013 - Employees were exposed to electrical hazards when working in their work stations around the General Electric junction box (240 volts) with missing knock-outs. c) On the north wall behind the Milltronics CNC Machine (serial number 6594, model number VM24E), on or about January 15, 2013 - Employees were exposed to electrical hazards when working in their work stations around the General Electric junction box (240 volts) with missing knock-outs. d) On the north wall behind the 4'x4' ZMD International, Inc. Thermomolder (serial number 1556, model number HD300), on or about January 15, 2013 - Employees were exposed to electracal hazards when working in their work stations around the General Electric junction box (240 volts) with missing knock-outs.
Recent events (2)
- — I (S) $1100
- — Z (S) $2000
1910.22 D01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.22(d)(1): On every building or other structure, or part thereof, used for mercantile, business, industrial or storage purposes, the loads approved by the building official were not marked on plates of approved design and securely affixed in a conspicuous place in each space to which they relate: a) At the facility, on or about January 15, 2013 - Employees were exposed to caught-in and struck-by hazards when an area of roof was used by the employer to store various unused and extra product without knowing the capacity of the structure's roof area.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 326122)
LINDSAY, CA—2026-07-13
NATIONAL DIVERSIFIED SALES, INC.
EUGENE, OR—2026-06-29
317744625 - ATKORE PLASTIC PIPE CORPORATION
RANTOUL, IL—2026-06-23
MAVERICK PIPE GROUP, LLC
MILLS, WY—2026-05-06
COWBOY STATE PLASTICS
PADUCAH, KY—2026-04-29
69082 - PLASTIC SERVICES AND PRODUCTS LLC
More inspections in TX
SPRING, TX—2026-07-10
DORSTENER WIRE TECH INC.
FORT WORTH, TX—2026-07-10
RC PROFESSIONAL ROOFING OF TEXAS LLC
CYPRESS, TX—2026-07-10
FEDERICO CARVAJAL GARCIA
SAN ANTONIO, TX—2026-07-10
ED LONG'S METAL WORKS
SAN ANTONIO, TX—2026-07-09
WAREHOUSE RACK COMPANY, LP
Source