MOUNT LAUREL, NJ —
OSHA Inspection: E&T PLASTICS
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of E&T PLASTICS in 824 EAST GATE DR SUITE E, MOUNT LAUREL, NJ 08054 (NAICS 326199). OSHA activity number 338314412.
Where did this inspection happen?
- Establishment
- E&T PLASTICS
- Site address
- 824 EAST GATE DR SUITE E
- City
- MOUNT LAUREL
- State
- NJ
- ZIP
- 08054
- Mailing
- 824 EAST GATE DR SUITE E, MOUNT LAUREL, NJ 08054
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326199
- Employees
- 8
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.133 A01
- Issued
- Penalty
- Initial $1200.00 · Current $600.00 Reduced
General-duty citation text
29 CFR 1910.133(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation: a) Production area: The employer did not ensure that employees using compressed air to clean wore safety glasses, on or about 1/17/13.
Recent events (2)
- — I (S) $600
- — Z (S) $1200
1910.242 B
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.242(b): Compressed air, that was not reduced to less than 30 p.s.i., was used for cleaning purposes without effective chip guarding and personal protective equipment. a) Production area: Employees used compressed air set above 120 psi to clean the panel saw. The air gun nozzle did not have a reducer attached to reduce the air to 30 psi and use of safety glasses was not mandatory, on or about 1/17/13.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.178 L01 I
- Issued
- Penalty
- Initial $1600.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator was competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): a) Production area: The employer did not evaluate the employees competency to operate the Komatsu FG25S model FG25S-4 type G serial 172791 and a Yale GLC050GNUAE082 serial E187V10265W forklifts, on or about 1/17/13.
Recent events (2)
- — I (S) $0
- — Z (S) $1600
1910.147 C04 I
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:(a)(LOCATION)(IDENTIFY SPECIFIC OPERATIONS AND/OR CONDITIONS)(IDENTIFY MACHINERY OR EQUIPMENT)(THIS INCLUDES ENFORCEMENT OF PROCEDURES) a) Production area: The employer did not develop and implement a lockout tagout program for employees when conducting maintenance and repair activities on the Schelling panel saw, such as, but not limited to, changing the saw blade, applying lubricant to the hydraulics and feeder wheels, cleaning the carriage and chains and repairing cables, on or about 1/17/13.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1910.157 G02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.157(g)(2): The educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting was not provided to all employees upon initial employment, and at least annually thereafter: a) Production area: employer did not provide training to employees required to use fire extinguishers that familiarized them with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting initially and annually thereafter, on or about 1/17/13.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at E&T PLASTICS
FORT LAUDERDALE, FL—2012-08-15 00:00:00
E T PLASTICS
View E&T PLASTICS's full OSHA safety record →
More inspections in this industry (NAICS 326199)
ERIE, PA—2026-07-14
CAPLUGS, LLC
CONNEAUT, OH—2026-07-13
CONTINENTAL STRUCTURAL PLASTICS
PETALUMA, CA—2026-07-10
LABCON NORTH AMERICA
KEEWATIN, MN—2026-07-09
111565 - TACKLE TAMER PRODUCTS INC
EAST FLAT ROCK, NC—2026-07-09
161517 - ELKAMET, INC.
More inspections in NJ
PERTH AMBOY, NJ—2026-07-16
ENGLERT INC.
RIDGEFIELD, NJ—2026-07-16
COLORITE PLASTICS COMPANY
BERLIN, NJ—2026-07-16
URUS CONSTRUCTION CORPORATION
GLASSBORO, NJ—2026-07-15
GLASSBORO WATER & SEWER DEPARTMENT
FLANDERS, NJ—2026-07-15
TRI-STATE QUIKRETE
Source