Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: JESSICA COLLINS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JESSICA COLLINS in 1414 HAMLET ST, COLUMBUS, OH 43201 (NAICS 238170). OSHA activity number 338321615.

Watch Jessica Collins — free Get an email when a new federal OSHA severe-injury report for Jessica Collins is published. One employer, no account, unsubscribe in one click.
Establishment
JESSICA COLLINS
Site address
1414 HAMLET ST
City
COLUMBUS
State
OH
ZIP
43201
Mailing
1298 BROWNLEAF ROAD, COLUMBUS, OH 43223
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238170
Employees
3
Ownership type
A

2 citations on file for this inspection.

1926.451 G01

Serious Gravity 10 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1960.00 Reduced
29 CFR 1926.451(g)(1):     Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level.     a.    At the site located at 1414 Hamlet St, Columbus, Ohio, employees were installing vinyl siding on the side of a residential home from a pump jack scaffold without conventional fall protection thereby exposing the employees to a fall hazard of approximately 12 feet.    b.    At the site located at 1414 Hamlet St, Columbus, Ohio, employees were installing vinyl siding on the back of a residential home from a pump jack scaffold without conventional fall protection thereby exposing the employees to a fall hazard of approximately 14 feet.
Recent events (2)
  • — I (S) $1960
  • — Z (S) $2800

1926.452 J02

Serious Gravity 10 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1960.00 Reduced
29 CFR 1926.452(j)(2):     Poles shall be secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. When the pump jack has to pass bracing already installed, an additional brace shall be installed approximately 4 feet (1.2 m) above the brace to be passed, and shall be left in place until the pump jack has been moved and the original brace reinstalled.    a.  At the site located at 1414 Hamlet Street, Columbus, Ohio employees were installing vinyl siding on the side of a residential home from a pump jack scaffold that was not braced at the bottom of the scaffold's poles, thereby exposing the employees to a fall hazard of 12 feet.    b.  At the site located at 1414 Hamlet Street, Columbus, Ohio employees were installing vinyl siding on the back of a residential home from a pump jack scaffold that was not braced at the bottom of the scaffold's poles, thereby exposing the employees to a fall hazard of 14 feet.
Recent events (2)
  • — I (S) $1960
  • — Z (S) $2800

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338321615.