MIAMI, FL —
OSHA Inspection: DESIGNERS TOPS, INC.
Follow-up inspection · Health discipline
At a glance
On , OSHA opened a follow-up health inspection of DESIGNERS TOPS, INC. in 1350 NW 88TH AVENUE, MIAMI, FL 33172 (NAICS 327991). OSHA activity number 338369036.
Where did this inspection happen?
- Establishment
- DESIGNERS TOPS, INC.
- Site address
- 1350 NW 88TH AVENUE
- City
- MIAMI
- State
- FL
- ZIP
- 33172
- Mailing
- 1350 NW 88TH AVENUE, MIAMI, FL 33172
What kind of inspection was it?
- Inspection type
- Follow-up (F)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 327991
- Employees
- 15
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.95 C01
- Issued
- Abate by
- Penalty
- Initial $4400.00 · Current $3000.00 Reduced
8110
General-duty citation text
29 CFR 1910.95(c)(1): The employer did not administer a continuing, effective hearing conservation program as described in 29 CFR 1910.9(c) through (o) whenever employee noise exposures equal or exceed an 8-hour time-weighted average sound level of 85 decibels measured on the A scale, or equivalently a dose of fifty percent: On or about February 26, 2013, at the above addressed jobsite: a) An employee working as a polisher was exposed to continuous noise at 232% of the permissible 8-hour Time Weighted Average sound level of 90 dBA, or an equivalent sound level of 96 dBA during a 454-minute sampling period. Zero exposure was assumed for the un-sampled period of time (26 minutes). b) An employee working as a fabricator was exposed to continuous noise at 233% of the permissible 8-hour Time Weighted Average sound level of 90 dBA, or an equivalent sound level of 96.1 dBA during a 454-minute sampling period. Zero exposure was assumed for the un-sampled period of time (26 minutes). c) An employee working as a wood worker was exposed to continuous noise at 66% of the permissible 8-hour Time Weighted Average sound level of 90 dBA, or an equivalent sound level of 87.1 dBA during a 454-minute sampling period. Zero exposure was assumed for the un-sampled period of time (26 minutes). The employer, Designers Tops, Inc. was previously cited for a violation of this occupational safety and health standard, CFR 1910.95(c)(1), which was contained in OSHA Inspection 315358515, Citation 1, Item 1, and affirmed as a final order on 3/23/2012, with respect to a workplace located at 1350 NW 88th Avenue, Miami, Florida 33172.
Recent events (2)
- — I (R) $3000
- — Z (R) $4400
1910.1000 C
- Issued
- Abate by
- Penalty
- Initial $4400.00 · Current $3000.00 Reduced
9010
General-duty citation text
29 CFR 1910.1000(c): Employees were exposed to Crystalline Silica, listed in Table Z-3, in excess of 0.511 mg/m3 as an 8-hour Time Weighted Average concentration. On or about February 26, 2013, at the above addressed jobsite, a countertop fabricator was exposed to an 8-hour Time Weighted Average (TWA) of 1.1 mg/m3 of crystalline silica. The permissible exposure limit (PEL) was 0.511 mg/m3 for a sample containing 16% quartz. The employee was sampled for 429 minutes with zero dose assumed for the un-sampled period. The employer, Designers Tops, Inc., was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CR 1910.1000(c), which was contained in OSHA inspection number 315358515, citation number 1 Item 3a and was affirmed as a final order on 3/23/2012, with respect to a workplace located at 1350 NW 88th Avenue, Miami, Florida 33172.
Recent events (2)
- — I (R) $3000
- — Z (R) $4400
1910.1000 E
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1000(e): Feasible administrative or engineering controls were not determined and implemented to achieve compliance with the limits prescribed in 29 CFR 1910.1000(a) through (d): On or about February 26, 2013, at the above addressed jobsite, the employer did not implement engineering or administrative controls for the countertop fabricator who was exposed to Silica. The 8-hour Time Weighted Average (TWA) for this employee was of 1.1 mg/m3 of crystalline silica. The permissible exposure limit (PEL) was 0.511 mg/m3 for a sample containing 16% quartz. The employee was sampled for 429 minutes with zero dose assumed for the un-sampled period. The employer, Designers Tops, Inc., was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CR 1910.1000(c), which was contained in OSHA inspection number 315358515, citation number 1 Item 3b and was affirmed as a final order on 3/23/2012, with respect to a workplace located at 1350 NW 88th Avenue, Miami, Florida 33172.
Recent events (2)
- — I (R) $0
- — Z (R) $0
More inspections at DESIGNERS TOPS, INC.
MIAMI, FL—2011-11-17 00:00:00
DESIGNERS TOPS, INC.
MIAMI, FL—2004-01-26 00:00:00
DESIGNERS TOPS INC.
View DESIGNERS TOPS, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 327991)
EL CAJON, CA—2026-07-16
GRANITE AND MARBLE CONCEPTS INC.
MURFREESBORO, TN—2026-07-16
EUROSTONE LLC
SANTA CLARA, CA—2026-07-15
UNITED MARBLE & GRANITE
RED LION, PA—2026-07-14
FRANK'S MARBLE & GRANITE, LLC.
MODESTO, CA—2026-07-13
EXQUISITE STONE DESIGN
More inspections in FL
MARIANNA, FL—2026-07-16
BRANNON BROTHERS CONSTRUCTION, LLC