Safety Incidents OSHA Severe Injury Reports · 2015–2025
3,913,242Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: DURA AUTOMOTIVE SYSTEMS LLC

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of DURA AUTOMOTIVE SYSTEMS LLC in 1855 ROBERTSON ROAD, MOBERLY, MO 65270 (NAICS 336340). OSHA activity number 338371057.

Watch Dura Automotive Systems LLC — free Get an email when a new federal OSHA severe-injury report for Dura Automotive Systems LLC is published. One employer, no account, unsubscribe in one click.
Site address
1855 ROBERTSON ROAD
City
MOBERLY
State
MO
ZIP
65270
Mailing
1855 ROBERTSON ROAD, MOBERLY, MO 65270
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336340
Employees
140
Ownership type
A

3 citations on file for this inspection.

1910.169 B03 III

Deleted Serious Gravity 5 4 instances 3 exposed
Issued
Abate by
Penalty
Initial $4000.00 · Current $0.00 Reduced
29 CFR 1910.169(b)(3)(iii):     Safety appliances such as safety valves, indicating devices and controlling devices, were not constructed, located, and/or installed so that they could not be readily rendered inoperative by any means, including the elements:    (a) On January 16th, 2013 employees of Dura Automotive were exposed to possible struck by hazards when multiple air pressure gauges had missing or broken cover glass or the gauge was broken or damaged in some other way.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4000

1910.303 B01

Serious Gravity 5 1 instance 3 exposed
Issued
Penalty
Initial $3400.00 · Current $2380.00 Reduced
29 CFR 1910.303(b)(1):     Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees:    (a) On January 16th, 2013 employees of Dura Automotive working in with machine P237 were exposed to contact with electrical current when live electrical components of an electrical pendant used to power a fan were exposed.
Recent events (2)
  • — I (S) $2380
  • — Z (S) $3400

1910.305 J02 IV

Serious Gravity 5 2 instances 3 exposed
Issued
Abate by
Penalty
Initial $4000.00 · Current $2800.00 Reduced
29 CFR 1910.305(j)(2)(iv):     A receptacle installed in a wet or damp location was not suitable for the location:     (a) On January 16th, 2013 employees of Dura Automotive working on press machines in the press area were exposed to contact with electrical current hazards when receptacles on the presses were not suitable for their wet environment.
Recent events (2)
  • — I (S) $2800
  • — Z (S) $4000