Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: CHRIS NOLAN

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CHRIS NOLAN in ACROSS FROM HODGE LN & FOSTERBURG RD., ALTON, IL 62002 (NAICS 238160). OSHA activity number 338428030.

Watch Chris Nolan — free Get an email when a new federal OSHA severe-injury report for Chris Nolan is published. One employer, no account, unsubscribe in one click.
Establishment
CHRIS NOLAN
Site address
ACROSS FROM HODGE LN & FOSTERBURG RD.
City
ALTON
State
IL
ZIP
62002
Mailing
213 CANTERBURY ST, BETHALTO, IL 62010
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
4
Ownership type
A

2 citations on file for this inspection.

1926.501 B13

Serious Gravity 5 1 instance 5 exposed
Issued
Penalty
Initial $2400.00 · Current $1200.00 Reduced
29 CFR 1926.501(b)(13):     "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502.  Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems.    Employees working from a 10 in 12 pitch roof were exposed to falls of approximately 9 feet 8 inches to a lower level. Employees were not protected from falling by guardrail systems, safety net systems, or a personal fall arrest systems or any other approved means.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2400

1926.1053 B01

Serious Gravity 5 1 instance 5 exposed
Issued
Penalty
Initial $2400.00 · Current $1200.00 Reduced
29 CFR 1926.1053(b)(1):     When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.    An extension ladder to access work on the roof did not extend three feet above the upper landing surface nor were there any grasping device, such as a grab rail to assist employees in mounting and dismounting the ladder.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2400

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338428030.