OSHA Inspection: PETITT POIS

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of PETITT POIS in 50 TWOSOME DR DUITE 3, MOORESTOWN, NJ 08057 (NAICS 424820). OSHA activity number 338451230.

Watch Petitt Pois — free Get an email when a new federal OSHA severe-injury report for Petitt Pois is published. One employer, no account, unsubscribe in one click.
Establishment
PETITT POIS
Site address
50 TWOSOME DR DUITE 3
City
MOORESTOWN
State
NJ
ZIP
08057
Mailing
50 TWOSOME DR DUITE 3, MOORESTOWN, NJ 08057
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
424820
Employees
14
Ownership type
A

3 citations on file for this inspection.

1910.178 L01 I

Serious Gravity 1 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $900.00 Reduced
29 CFR 1910.178(l)(1)(i):     The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):      a) Warehouse: Employees that received forklift certification from their previous employers were not evaluated to determine their competency before operating the  Komatsu FG15S model FG15ST-2 serial 182758A forklift, on or about 1/25/13.
Recent events (2)
  • — I (S) $900
  • — Z (S) $1200

1910.305 G01 IV C

Serious Gravity 1 2 instances 4 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $900.00 Reduced
29 CFR 1910.305 (g)(1)(iv)(C)     Flexible cords and or cables were run through doorways, windows or similar openings:    a) Warehouse near scale: An extension cord, used to charge the engine in a 22 foot long box truck, was run to the outside under the emergency exit door, on or about 1/25/13.     b) Warehouse near center receiving door: An extension cord, used to charge the engine in a work van, was run to the outside under an overhead door, on or about 1/25/13.
Recent events (2)
  • — I (S) $900
  • — Z (S) $1200

1910.157 G02

Other-than-serious 1 instance 14 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.157(g)(2):     The educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting was not provided to all employees upon initial employment, and at least annually thereafter:    a) Throughout facility: Employees were not provided training on fire extinguishers initially upon hire and annually thereafter, on or about 1/25/13.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0