OSHA Inspection: KEAL CASE

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of KEAL CASE in 1100 WEST OLD SETTLERS BLVD, ROUND ROCK, TX 78680 (NAICS 321920). OSHA activity number 338485238.

Watch Keal Case — free Get an email when a new federal OSHA severe-injury report for Keal Case is published. One employer, no account, unsubscribe in one click.
Establishment
KEAL CASE
Site address
1100 WEST OLD SETTLERS BLVD
City
ROUND ROCK
State
TX
ZIP
78680
Mailing
1100 WEST OLD SETTLERS BLVD, ROUND ROCK, TX 78680
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321920
Employees
22
Ownership type
A

11 citations on file for this inspection.

1910.95 C01

Serious Gravity 5 1 instance 22 exposed
Issued
Abate by
Penalty
Initial $2400.00 · Current $1440.00 Reduced
29 CFR 1910.95(c)(1): The employer did not administer a continuing, effective hearing conservation program as described in 29 CFR 1910.9(c) through (o) whenever employee noise exposures equal or exceed an 8-hour time-weighted average sound level of 85 decibels measured on the A scale, or equivalently a dose of fifty percent:    On or about January 29, 2013, the employer did not institute an effective hearing conservation program for employees exposed to noise levels in excess of the allowable 8-hour Time Weighted Average (TWA) sound level of 85 dBA.    a:  Noise sampling performed on wood worker, for 450 minutes indicated that the employee was exposed to a 63.4% noise dose which is equivalent to approximately 87.1 dBA.    b:  Noise sampling performed on aluminum cutter, for 453 minutes indicated that the employee was exposed to a 148.4% dose which is equivalent to approximately 93.3 dBA.    Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that a hearing conservation program is created and implemented for all employees exposed to high levels of noise.  The program must include monitoring, audiometric testing, and training for affected employees.
Recent events (2)
  • — I (S) $1440
  • — Z (S) $2400

1910.107 B05 I

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $720.00 Reduced
29 CFR 1910.107(b)(5)(i): Visible gauges or audible alarm or pressure activated devices were not installed to indicate or insure that the required air velocity is maintained.     On or about January 25, 2013, the employer did not ensure that the booth's pressure gauge was visible and working, exposing employees to the hazards of chemical inhalation and fire.	  Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that the booths pressure gauge is visible and working.
Recent events (2)
  • — I (S) $720
  • — Z (S) $1200

1910.107 B05 IV

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.107(b)(5)(iv): Space within the spray booth on the downstream and upstream sides of filters were not protected with approved automatic sprinklers:  On or about January 25, 2013, the employer did not ensure that sprinkler heads were installed on the up and down stream sides of the spray booth filter, exposing employees to the hazards of fire.  	  Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that fire suppression sprinklers are installed on up and down stream sides of the spray booth filter.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.107 B09

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.107(b)(9): A clear space of not less than 3 feet on all sides was not kept free from storage or combustible construction:  On or about January 25, 2013, the employer did not ensure that a three foot clear space around the spray booth was kept free from storage, exposing the employees to the hazards of fire.	  Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that a three foot clear space is maintained around the spray booth.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 E01

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $720.00 Reduced
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:  On or about January 25, 2013, and at times prior thereto, the employer required staff to wear respirators while working in the spray booth without ensuring each was medically evaluated prior to fit testing and using the respirator, exposing employees to an additional burden to their cardiopulmonary system.  Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that all employees required to use a tight fighting respirator are medically evaluated prior to respirator use.
Recent events (2)
  • — I (S) $720
  • — Z (S) $1200

1910.134 F02

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator, and at least annually thereafter:  On or about January 25, 2013, and at times prior thereto, the employer required maintenance staff to wear respirators while working in the spray booth without ensuring each employee is fit tested prior to use and at least annually thereafter, exposing employees to inhalation hazards.   Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that all employees required to use a tight fighting respirator are fit tested.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A02

Serious Gravity 5 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1200.00 Reduced
29 CFR 1910.212(a)(2): Guard(s) on machine(s) were not affixed to the machine or secured elsewhere when attachment to the machine was not possible:  On or about January 25, 2013, a Bosch 1575A hand foam cutter was mounted to the underside of a table with the blade passing through a hole in the table.  The unused portion of the blade was unguarded, exposing employees to the hazard of being struck by the blade.    Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure machine guarding is in place to protect employees from accidental contact nip points, rotating parts, flying chips, saw blades, etc.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1910.305 A04 IV

Serious Gravity 1 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $720.00 Reduced
29 CFR 1910.305(a)(4)(iv): Open conductors were not separated from contact with walls, floors, wood cross members, or partitions through which they passed, by tubes or bushings of noncombustible, nonabsorbent insulating material:  On or about July 25, 2013, an open conductor connected to a snap switch was not separated from the wood cross member of the foam cutting table, exposing employees to the hazards of electrical shock and/ or fire.  Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that open conductors are separated from contact with walls, floors, wood cross members, or partitions through which they pass by tubes or bushings of noncombustible, nonabsorbent insulating material.
Recent events (2)
  • — I (S) $720
  • — Z (S) $1200

1910.305 B01 I

Serious Gravity 1 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(b)(1)(i): Conductors entering cutout boxes, cabinets, or fittings were not protected from abrasions:  On or about January 25, 2013, a wire entering a receptacle box under the foam cutting table was not protected from abrasion, exposing employees to an electrical shock hazard.    Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that wiring entering and exiting boxes is protected from abrasion.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 F01

Serious Gravity 1 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(f)(1): Conductors used for general wiring were not insulated:  On or about January 25, 2012, a wire entering a snap switch that powered the foam cutter was missing most of the outer jacket of insulation, exposing employees to an electrical shock hazard.      Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that wiring is fully insulated.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G02 II

Serious Gravity 1 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(2)(ii): Flexible cords were not used only in continuous lengths without splice or tap:  On or about July 25, 2013, a flexible cable was cut and used to power a receptacle box which, in turn, powered the Bosch foam cutter, exposing employees to the hazards of electrical shock.  Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that flexible cords are used in continuous lengths without splices or taps.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0