Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: DUTTON-LAINSON COMPANY

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DUTTON-LAINSON COMPANY in 1900 SUMMIT AVE., HASTINGS, NE 68902 (NAICS 332420). OSHA activity number 338564636.

Watch Dutton-Lainson Company — free Get an email when a new federal OSHA severe-injury report for Dutton-Lainson Company is published. One employer, no account, unsubscribe in one click.
Site address
1900 SUMMIT AVE.
City
HASTINGS
State
NE
ZIP
68902
Mailing
PO BOX 1007, HASTINGS, NE 68902
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332420
Employees
32
Ownership type
A

10 citations on file for this inspection.

1910.23 E03 V C

Serious Gravity 1 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $3000.00 · Current $1500.00 Reduced
29 CFR 1910.23(e)(3)(v)(c)      Protection between the top rail and stair treads, shall be equivalent at least to that afforded by a standard intermediate rail.      On the stairs leading up to the mezzanine area above maintenance the employer is failing to ensure that the stair rail is equipped with a mid-rail.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $3000

1910.178 G02

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $4000.00 · Current $2800.00 Reduced
29 CFR 1910.178(g)(2)    Battery changing and charging installations for industrial trucks were not provided with adequate protection of charging apparatus from damage by trucks.    In the saw area of the tacitly the employer is failing to protect the Pac-Chloride Mark I charging unit from damage by fork lifts.
Recent events (2)
  • — I (S) $2800
  • — Z (S) $4000

1910.212 A01

Serious Gravity 10 2 instances 4 exposed
Issued
Abate by
Penalty
Initial $7000.00 · Current $4000.00 Reduced
29 CFR 1910.212(a)(1):     One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, in-running nip point, rotating parts, flying chips and sparks:    In the press break area of the facility the employer is failing to protect employees from the hazards machines by not properly guarding equipment including but not limited to the following:    "	Cincinnati PB06 Press Brake  "	Accurpress PB03 Press Brake
Recent events (2)
  • — I (S) $4000
  • — Z (S) $7000

1910.213 I01

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $5000.00 · Current $3500.00 Reduced
29 CFR 1910.213(i)(1):      Non-working portion(s) of the blade of bandsaw(s) were not enclosed or guarded:    In the Saw Area of the facility the employer is failing to ensure that all unused portion of the blade guarded on the Vertical Band Saw marked VB01.
Recent events (2)
  • — I (S) $3500
  • — Z (S) $5000

1910.215 B09

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $4000.00 · Current $2000.00 Reduced
29 CFR 1910.215(b)(9):      The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:                                                       In maintenance shop area of the facility the employer is failing to ensure the bench grinders tongue guard was adjusted to within one fourth inch of the outer surface of the abrasive wheel.   The periphery of the wheel was 3/4 inch from the bottom of the tongue guard.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $4000

1910.219 D01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $5000.00 · Current $3500.00 Reduced
29 CFR 1910.219(d)(1):     Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):       At the facility on the South wall the employer is failing to ensure that the pulley used to transmit power to on the Circle Sheer CS02 was not guarded in accordance with this subpart.
Recent events (2)
  • — I (S) $3500
  • — Z (S) $5000

1910.219 E01 I

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.219(e)(1)(i):     Horizontal belts which had both runs 42 inches or less from the floor level were not fully enclosed by guards conforming to requirements specified in 29 CFR 1910.219(m) and (o):    At the facility on the South wall the employer is failing to ensure that the belt(s) used to transmit power to on the Circle Sheer CS02 was not guarded in accordance with this subpart.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 B01 II

Deleted Serious Gravity 5 1 instance 20 exposed
Issued
Abate by
Penalty
Initial $4000.00 · Current $0.00 Reduced
29 CFR 1910.303(b)(1)(ii):      Electrical equipment was not free from recognized hazards, based on the mechanical strength and durability, including, for parts designed to enclose and protect other equipment, the adequacy of the protection thus provided:    In the nitrogen storage area the employer is failing to ensure that the 110V electrical outlet cover was not damaged exposing live conductors.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4000

1910.305 G01 III

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $4000.00 · Current $2800.00 Reduced
29 CFR 1910.305(g)(1)(iii):     Flexible cords and cables were used for purposes prohibited by subparagraphs (A) through (E) of this paragraph:                                                                                   In the shipping area of the facility the employer is failing to ensure employees are protected from electrical hazards in that an extension cord is being used as a substitute for permanent wiring in that the extension cord was attached with the use of wire to a storage shelf.
Recent events (2)
  • — I (S) $2800
  • — Z (S) $4000

1910.305 G01 IV C

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(1)(iv)(C):      Flexible cords and cables were run through doorways, windows, or similar openings;     On the North Wall of the facility the employer is failing to ensure that flexible cords are not run through doorways:
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View DUTTON-LAINSON COMPANY's full OSHA safety record →