OSHA Inspection: DAVE CONSTABLE HOME IMPROVEMENT SPECIALIST, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of DAVE CONSTABLE HOME IMPROVEMENT SPECIALIST, INC. in 9452 MAIN STREET, STATE ROUTE 365, HOLLAND PATENT, NY 13354 (NAICS 236220). OSHA activity number 338585433.

Watch Dave Constable Home Improvement Specialist, INC. — free Get an email when a new federal OSHA severe-injury report for Dave Constable Home Improvement Specialist, INC. is published. One employer, no account, unsubscribe in one click.
Site address
9452 MAIN STREET, STATE ROUTE 365
City
HOLLAND PATENT
State
NY
ZIP
13354
Mailing
9808 STATE ROUTE 365, HOLLAND PATENT, NY 13354
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
4
Ownership type
A

5 citations on file for this inspection.

1926.304 I01

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $0.00 Reduced
29 CFR 1926.304(i)(1):  Each circular had-fed ripsaw was not guarded by a hood whcih completely enclosed that portion of the saw above the table and that portion of the saw above the material being cut:    a) North end of building, on or about 1-31-13:  One employee was ripping framing lumber and plywood on a table saw that was not equipped with a hood guard that automatically adjusts to enclose the saw blade.
Recent events (3)
  • — J (S) $0
  • — C (S) $2000
  • — Z (S) $2000

1926.304 F

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
1926.304(f)  Section 4.1.2(b)  American National Standards Institute 01.1-1961, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f):  Circular hand-fed rip saws were not equipped with a spreader to prevent material from squeezing the saw or being thrown back on the operator:     1926.304(f)  Section 4.1.2(c)  American National Standards Institute 01.1-1961, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f):  Circular hand-fed rip saws did not have non-kickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator:     1926.304(f)  Section 5.1.3.3  American National Standards Institute 01.1-1975, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f):  Electrically driven equipment was not equipped with magnetic switches or other devices that will prevent automatic restarting of the machine after a power failure:    a) North end of building, on or about 1-31-13:  One employee was ripping framing lumber and plywood on a table saw that was not equipped with a spreader.    b) North end of building, on or about 1-31-13:  One employee was ripping framing lumber and plywood on a table saw that was not equipped with non kick-back fingers or dogs.    c) North end of building, on or about 1-31-13:  One employee was ripping framing lumber and plywood on a table saw that was not equipped with a magnetic switch or anti-restart device.
Recent events (3)
  • — J (S) $0
  • — C (S) $0
  • — Z (S) $0

1926.404 B01 II

Deleted Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $0.00 Reduced
29 CFR 1926.404(b)(1)(ii):  On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupers for personal protection:    a) North end of building, on or about 1-31-13:  One employee was operating various power tools, powered through an extension cord, plugged into a duplex receptacle that was not protected by a ground fault circuit interrupter (GFCI).
Recent events (3)
  • — J (S) $0
  • — C (S) $1200
  • — Z (S) $1200

1926.451 F06

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $0.00 Reduced
29 CFR 1926.451(f)(6):  Scaffolds were erected, used, dismantled, altered, or moved such that they, or any conductive material handled on them, could have come closer than the minimum distances established for specific voltages as set forth in the table in subparagraph (f)(6):    a) Northeast corner of building, on or about 1-31-13:  One employee was working on a scaffold system that was erected within 1inch of energized power lines.
Recent events (3)
  • — J (S) $0
  • — C (S) $2000
  • — Z (S) $2000

1926.451 G04 I

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $0.00 Reduced
29 CFR 1926.451(g)(4)(i):  Guardrail systems were not installed along all open sides and ends of platforms:    a) North side of building, on or about 1-31-13:  One employee was working on a scaffold platform with no mid rail, exposing the employee to a fall hazard of 12 feet 8 inches.
Recent events (3)
  • — J (S) $0
  • — C (S) $2000
  • — Z (S) $2000