Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: ECOCOR BUILDING & DESIGN, LLC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of ECOCOR BUILDING & DESIGN, LLC. in 11 GOLDFINCH LANE, SURRY, ME 04684 (NAICS 236115). OSHA activity number 338604648.

Watch Ecocor Building & Design, LLC. — free Get an email when a new federal OSHA severe-injury report for Ecocor Building & Design, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
11 GOLDFINCH LANE
City
SURRY
State
ME
ZIP
04684
Mailing
P.O. BOX 454, BELFAST, ME 04915
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236115
Employees
5
Ownership type
A

6 citations on file for this inspection.

1926.451 C02

Serious Gravity 5 10 instances 3 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1400.00 Reduced
29 CFR 1926.451(c)(2):    Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation:    In the following instances supported scaffold legs did not bear on adequate firm foundations:    a)  Southwest Scaffold - On or about 1/29/13, three scaffold legs did not bear on firm foundations.  b)  Southeast Scaffold - On or about 1/29/13, four scaffold legs did not bear on firm foundations.  c)  Northeast Scaffold - On or about 1/29/13, two scaffold legs did not bear on firm foundations.  d)  Southern Porch - On or about 1/10/13, an employee, utilizing a fabricated frame scaffold, fell when at least one of the scaffold legs broke through a sheet of OSB.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2000

1926.451 G01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1400.00 Reduced
29 CFR 1926.451(g)(1):   Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level:    Southwest Scaffold - On or about 1/23/13, an employee on the scaffold 10.75 feet above the ground was not protected from falling.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2000

1926.454 B

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1400.00 Reduced
29 CFR 1926.454(b):   The employer shall have each employee who is involved in erecting, disassembling, moving, operating, repairing, maintaining, or inspecting a scaffold trained by a competent person to recognize any hazards associated with the work in question:    Worksite - The employees utilizing, erecting, and maintaining fabricated frame and pump jack scaffolds were not trained by a competent person.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2000

1926.451 F03

Serious Gravity 5 5 instances 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(f)(3):  Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity.    Worksite - Scaffolds and scaffold components were not inspected by a competent person before each work shift.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.452 C02

Other-than-serious 21 instances 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.452(c)(2):    Frames and panels shall be braced by cross, horizontal, or diagonal braces, or combination thereof, which secure vertical members together laterally. The cross braces shall be of such length as will automatically square and align vertical members so that the erected scaffold is always plumb, level, and square. All brace connections shall be secured.    In the following instances fabricated frame scaffolds were not adequately braced:    a)  Southwest Scaffold - Four cross braces were missing.  b)  Southeast Scaffold - Eight cross braces were missing.  c)  Northeast Scaffold - Four cross braces were missing.  d)  West Scaffold - Five cross braces were missing.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1926.452 J02

Other-than-serious 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.452(j)(2):   Poles shall be secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. When the pump jack has to pass bracing already installed, an additional brace shall be installed approximately 4 feet (1.2 m) above the brace to be passed, and shall be left in place until the pump jack has been moved and the original brace reinstalled.    East Scaffold - The two poles on the pump jack scaffold were not equipped with bottom braces.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338604648.