SURRY, ME —
OSHA Inspection: ECOCOR BUILDING & DESIGN, LLC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of ECOCOR BUILDING & DESIGN, LLC. in 11 GOLDFINCH LANE, SURRY, ME 04684 (NAICS 236115). OSHA activity number 338604648.
Where did this inspection happen?
- Establishment
- ECOCOR BUILDING & DESIGN, LLC.
- Site address
- 11 GOLDFINCH LANE
- City
- SURRY
- State
- ME
- ZIP
- 04684
- Mailing
- P.O. BOX 454, BELFAST, ME 04915
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236115
- Employees
- 5
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.451 C02
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1400.00 Reduced
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation: In the following instances supported scaffold legs did not bear on adequate firm foundations: a) Southwest Scaffold - On or about 1/29/13, three scaffold legs did not bear on firm foundations. b) Southeast Scaffold - On or about 1/29/13, four scaffold legs did not bear on firm foundations. c) Northeast Scaffold - On or about 1/29/13, two scaffold legs did not bear on firm foundations. d) Southern Porch - On or about 1/10/13, an employee, utilizing a fabricated frame scaffold, fell when at least one of the scaffold legs broke through a sheet of OSB.
Recent events (2)
- — I (S) $1400
- — Z (S) $2000
1926.451 G01
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1400.00 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level: Southwest Scaffold - On or about 1/23/13, an employee on the scaffold 10.75 feet above the ground was not protected from falling.
Recent events (2)
- — I (S) $1400
- — Z (S) $2000
1926.454 B
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1400.00 Reduced
General-duty citation text
29 CFR 1926.454(b): The employer shall have each employee who is involved in erecting, disassembling, moving, operating, repairing, maintaining, or inspecting a scaffold trained by a competent person to recognize any hazards associated with the work in question: Worksite - The employees utilizing, erecting, and maintaining fabricated frame and pump jack scaffolds were not trained by a competent person.
Recent events (2)
- — I (S) $1400
- — Z (S) $2000
1926.451 F03
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(f)(3): Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity. Worksite - Scaffolds and scaffold components were not inspected by a competent person before each work shift.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.452 C02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.452(c)(2): Frames and panels shall be braced by cross, horizontal, or diagonal braces, or combination thereof, which secure vertical members together laterally. The cross braces shall be of such length as will automatically square and align vertical members so that the erected scaffold is always plumb, level, and square. All brace connections shall be secured. In the following instances fabricated frame scaffolds were not adequately braced: a) Southwest Scaffold - Four cross braces were missing. b) Southeast Scaffold - Eight cross braces were missing. c) Northeast Scaffold - Four cross braces were missing. d) West Scaffold - Five cross braces were missing.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1926.452 J02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.452(j)(2): Poles shall be secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. When the pump jack has to pass bracing already installed, an additional brace shall be installed approximately 4 feet (1.2 m) above the brace to be passed, and shall be left in place until the pump jack has been moved and the original brace reinstalled. East Scaffold - The two poles on the pump jack scaffold were not equipped with bottom braces.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 236115)
CARSON CITY, NV—2026-07-16
LT BUILDERS
FAIRVIEW, TN—2026-07-16
DRB GROUP TENNESSEE, LLC
DOVER, NH—2026-07-15
KNOX MARSH DEVELOPMENT LLC
VIENNA, VA—2026-07-15
OMARI CONSTRUCTION LLC
NORFOLK, VA—2026-07-15
SUPERIOR PRIDE INC
More inspections in ME
AUGUSTA, ME—2026-07-14
JJ GONZALEZ ROOFING AND GUTTERS
DOVER FOXCROFT, ME—2026-07-14
REDI-ROCK OF CENTRAL MAINE
PORTLAND, ME—2026-07-06
NEW ENGLAND REHABILITATION HOSPITAL OF PORTLAND
DOVER FOXCROFT, ME—2026-07-06
SHAW'S SUPERMARKETS
GORHAM, ME—2026-07-02
TOWN OF GORHAM
Source