Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: SWJ CONSTRUCTORS, LLC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SWJ CONSTRUCTORS, LLC. in 1120 SPANISH TOWN, BATON ROUGE, LA 70802 (NAICS 236116). OSHA activity number 338628431.

Watch SWJ Constructors, LLC. — free Get an email when a new federal OSHA severe-injury report for SWJ Constructors, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
1120 SPANISH TOWN
City
BATON ROUGE
State
LA
ZIP
70802
Mailing
118 MAYERS TRACE, SLIDELL, LA 70460
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236116
Employees
25
Ownership type
A

4 citations on file for this inspection.

1926.404 F06

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1870.00 · Current $0.00 Reduced
29 CFR 1926.404(f)(6):     Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent and continuous.    a)	On or about January 1, 2013; at the center of the jobsite, the employer allowed employees to utilize an extension cord that was missing a ground pin.  The extension cord was used to deliver power from an outlet box to a series of extension cords, which were used to energize two (2) hand-held drills.  Employees used the hand-held drills to install ceiling channel.  The missing ground pin prevented the extension cord from having a continuous path to ground.
Recent events (2)
  • — I (S) $0
  • — Z (S) $1870

1926.405 G02 IV

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1870.00 · Current $935.00 Reduced
29 CFR 1926.405(g)(2)(iv):     Strain relief. Flexible cords shall be connected to devices and fittings so that strain relief is provided which will prevent pull from being directly transmitted to joints or terminal screws.    a)	On or about January 1, 2013; at the center of the jobsite, the employer allowed employees to utilize an extension cord with inadequate strain relief in order to power two (2) hand-held drills.  Employees used the hand-held drills to install ceiling channel.
Recent events (2)
  • — I (S) $935
  • — Z (S) $1870

1926.416 E01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1870.00 · Current $0.00 Reduced
29 CFR 1926.416(e)(1):     Worn or frayed electric cords or cables shall not be used.    a)	On or about January 1, 2013; at the center of the jobsite, the employer allowed employees to utilize a damaged extension cord to power a hand-held drill.  Employees used the hand-held drill to install ceiling channel.
Recent events (2)
  • — I (S) $0
  • — Z (S) $1870

1926.403 B02

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.403(b)(2):     Installation and use. Listed, labeled, or certified equipment shall be installed and used in accordance with instructions included in the listing, labeling, or certification.    a)	On or about January 1, 2013; at the center of the jobsite, the employer allowed employees to utilize extension cords in a manner that was not in accordance with instructions included in the labeling.  Employees connected extension cords together to create a chain of three (3) extension cords and one (1) multi-tap cord in order to power two (2) hand-held drills.  Employees used the hand-held drills to install ceiling channel.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View SWJ CONSTRUCTORS, LLC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338628431.