MORRISTOWN, NJ —
OSHA Inspection: JORGE TENESACA CONSTRUCTION
Special Programs inspection · Safety discipline
At a glance
On , OSHA opened a special Programs safety inspection of JORGE TENESACA CONSTRUCTION in 7 MAPLE AVENUE, MORRISTOWN, NJ 07960 (NAICS 238170). OSHA activity number 338650831.
Where did this inspection happen?
- Establishment
- JORGE TENESACA CONSTRUCTION
- Site address
- 7 MAPLE AVENUE
- City
- MORRISTOWN
- State
- NJ
- ZIP
- 07960
- Mailing
- 345 HILLSIDE AVENUE, HILLSIDE, NJ 07205
What kind of inspection was it?
- Inspection type
- Special Programs (K)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238170
- Employees
- 4
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B13
- Issued
- Penalty
- Initial $2800.00 · Current $2800.00
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. 7 Maple Avenue, Morristown, NJ - Third story roof Employees engaged in residential siding finishing work from the third story roof were not protected from falls by use of a guardrail system, safety net system, or personal fall arrest system. Violation observed on or about December 10, 2012
Recent events (1)
- — Z (S) $2800
1926.1053 B01
- Issued
- Penalty
- Initial $2800.00 · Current $2800.00
General-duty citation text
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access. a. 7 Maple Avenue, Morristown, NJ Aluminum extension ladder used for access to the third story roof did not extend at least 3-feet above the landing surface to which the ladder was used to gain access. Violation observed on or about December 10, 2012
Recent events (1)
- — Z (S) $2800
More inspections in this industry (NAICS 238170)
CLINTON, MO—2026-07-14
TORCHYLO BUILDERS, LLC.
HIGH POINT, NC—2026-07-14
161545 - RHP SIDING LLC
HIGH POINT, NC—2026-07-14
161544 - TRIAD SIDING OF THOMASVILLE INCORPORATED
OXFORD, OH—2026-07-13
R&R SIDING LLC
WINSTON SALEM, NC—2026-07-10
161522 - MS SIDING LLC
More inspections in NJ
PERTH AMBOY, NJ—2026-07-16
ENGLERT INC.
RIDGEFIELD, NJ—2026-07-16
COLORITE PLASTICS COMPANY
BERLIN, NJ—2026-07-16
URUS CONSTRUCTION CORPORATION
GLASSBORO, NJ—2026-07-15
GLASSBORO WATER & SEWER DEPARTMENT
FLANDERS, NJ—2026-07-15
TRI-STATE QUIKRETE
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338650831.