KAHULUI, HI —
OSHA Inspection: MAUI CUSTOM WOODWORKS, INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of MAUI CUSTOM WOODWORKS, INC. in 251 LALO STREET SUITE L1, KAHULUI, HI 96732 (NAICS 337110). OSHA activity number 338788631.
Where did this inspection happen?
- Establishment
- MAUI CUSTOM WOODWORKS, INC.
- Site address
- 251 LALO STREET SUITE L1
- City
- KAHULUI
- State
- HI
- ZIP
- 96732
- Mailing
- 251 LALO STREET SUITE L1, KAHULUI, HI 96732
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337110
- Employees
- 16
- Ownership type
- A
Citations
6 citations on file for this inspection.
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $2100.00 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm including severe burns to employees in that employees were exposed to dust explosion, deflagration or other fire hazards from dust collectors being located inside a building: (a) At Maui Custom Woodworking, Inc. on or about February 1, 2013 a cyclone collector was located indoors; and (b) At Maui Custom Woodworking, Inc. on or about Februatry 1, 2013 bag collectors from saws and other equipment were located indoors.
Recent events (2)
- — I (S) $2100
- — Z (S) $2800
1910.22 A01
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $2100.00 Reduced
General-duty citation text
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition. (a) At Maui Custom Woodworking, Inc. on or about February 1, 2013 the elevated surfaces in the cabinet manurfacturing area were not kept clear of the accumulation of explosive dust.
Recent events (2)
- — I (S) $2100
- — Z (S) $2800
1910.23 C01
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1500.00 Reduced
General-duty citation text
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards: (a) At Maui Custom Woodworking, Inc. on or about February 1, 2013 the guardrail on the deck above the woodworking area was not guarded its full length by a standard guardrail. Approximately 10 feet of the railing was missing a midrail.
Recent events (2)
- — I (S) $1500
- — Z (S) $2000
1910.213 D01
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1500.00 Reduced
General-duty citation text
29 CFR 1910.213(d)(1): Circular handfed crosscut table saw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut: (a) At Maui Custom Woodworking, Inc. on or about February 1, 2013 the table saw on the deck used for making crosscuts did not have a guard that enclosed the portion of the saw above the table and above the material being cut.
Recent events (2)
- — I (S) $1500
- — Z (S) $2000
1910.304 G05
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: (a) At Maui Custom Woodworking, Inc. on or about February 1, 2013 the path to ground on the portable fan in the cabinet shop was missing the grounding pin on the attachment cord.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 A02 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(a)(2)(i): Temporary electrical power and lighting installation(s) 600 volts, nominal, or less were used in prohibited manners: (a) At Maui Custom Woodworking, Inc. on or about February 1, 2013 an electrical cord was used in place of permanent wiring to power a saw running from the second floor to the first floor.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 337110)
OAKLAND PARK, FL—2026-07-16
PKB CABINETRY
ORLANDO, FL—2026-07-15
ROSTOV, LLC
RICHMOND HILL, GA—2026-07-14
WILSON CABINETRY, LLC
VESTAL, NY—2026-07-08
BARNWOOD KITCHEN CABINETS
DEERWOOD, MN—2026-07-02
111522 - DUFFNEY CUSTOM CABINETS LLC
More inspections in HI
LAHAINA, HI—2026-07-15
PALI KOA LLC
HONOLULU, HI—2026-07-14
KAIKAI WANG
KAILUA, HI—2026-07-08
HELEMAI LAWN & GARDEN
MAKAWAO, HI—2026-07-01
HALIIMAILE PINEAPPLE COMPANY LTD
HONOLULU, HI—2026-06-29
GP ENERGY COMPANY LLC
Source